摘要
对火力发电厂厂用电快切装置的工作原理、运行特点进行了分析、阐述,并引用神头第二发电厂实例进行了故障分析,总结了快切装置在发电厂实际运行中的常见问题和解决办法。
This article states and analyzes the working principles and operating characteristics of the auxiliary power fast switchover device used in thermal power plant. Taking the practical examples of Shanxi Shentou Electric Power Plant, it provides fault analysis and summarizes the common problems of fast switchover device and their solutions in the operation of electric power plants.
出处
《山西电力》
2013年第1期57-59,共3页
Shanxi Electric Power
关键词
厂用电
快切
火力发电厂
auxiliary power
fast switchover device
thermal power plant