期刊文献+

64层螺旋CT结合多时相重建诊断冠状动脉疾病的价值

64 Layer Spiral CT Combined with Long Phase Reconstruction Diagnosis Value of Coronary Artery Disease
暂未订购
导出
摘要 目的通过64层螺旋CT结合多时相重建,探讨诊断冠状动脉疾病的价值。方法采用日本Toshiba公司(Aquil-ion64)螺旋CT机,用双筒高压注射器,采用手动或自动触发扫描。结果 70例患者中,共显示530支血管,显示冠状动脉的敏感性为95%,假阴性率为2%,假阳性率为4%,阳性预测值为95%,阴性预测值为97%。结论相对于CCA(选择性冠状动脉造影)而言,64SCTCA是一种无创检查,花费少,更适宜作为一种筛查手段用于冠心病的诊断。 Objective Through the 64 layer spiral CT combined with long phase reconstruction ,this paper discusses the diagnosis value of coronary artery disease. Methods Uses the Japanese Toshiba company( Aquilion64 )spiral CT machine, with double barrel high pressure syringe, using manual or automatic trigger scanning. Results In 70 patients, A total of 530 show a blood vessel, coronary arter- ies showed a sensitivity of 95 %, the false negative rate was 2% ,the false positive rate was 4% , the positive predictive value was 95 % , the negative predir:live value was 97%. Coneluslon Relative to the CCA( selective coronary angioraphy) ,64SCTCA is a noninvasive, inexpensive, more suitable as a screening tool for the diagnosis of coronary heart disease.
出处 《哈尔滨医药》 2013年第1期24-26,共3页 Harbin Medical Journal
关键词 冠状动脉疾病 多时相重建 64层螺旋CT Coronary diseases Multi -phasic rebuilding 64 layer spiral CT
  • 相关文献

参考文献2

二级参考文献23

  • 1雷子乔,韩萍,孔祥泉,梁波,田志梁,李友林,梁明.多层螺旋CT冠状动脉造影扫描技术及图像质量的影响因素[J].临床放射学杂志,2005,24(1):77-80. 被引量:40
  • 2陈艳,韩萍,梁波,雷子乔,田志梁,周阳泱.多层螺旋CT冠状动脉成像:重建时相及心率对图像质量的影响[J].中国医学影像技术,2005,21(3):425-429. 被引量:30
  • 3Kopp AF,Schroeder S,Kuettner A,et al.Coronary arteries:retrospectively ECG-gated multi-detector row CT angiography with selective optimization of the image reconstruction window.Radiology,2001,221:683-688.
  • 4Achenbach S,Ulzheimer S,Baum U,et al.Noninvasive coronary angiography by retrospectively ECG-gated multislice spiral CT.Circulation,2000,102:2823-2828.
  • 5De Feyter PJ,Nieman K.New coronary imaging techniques:what to expect.Heart,2002,87:195-197.
  • 6Peebles CR.Non-invasive coronary imaging:computed tomography or magnetic resonance imaging? Heart,2003,89:591-594.
  • 7Hong C,Becker CR,Huber A,et al.ECG-gated reconstructed multi-detector row CT coronary angiography:effect of varying trigger delay on image quality.Radiology,2001,220:712-717.
  • 8Vogl TJ,Abolmaali ND,Diebold T,et al.Techniques for the detection of coronary atherosclerosis:multi-detector row CT coronary angiography.Radiology,2002,223:212-220.
  • 9Achenbach S,Giesler T,Ropers D,et al.Detection of coronary artery stenoses by contrast-enhanced,retrospectively electrocardiographically-gated,multislice spiral computed tomography.Circulation,2001,103:2535-2538.
  • 10Nieman K,Rensing BJ,van Geuns RJ,et al.Non-invasive coronary angiography with multislice spiral computed tomography:impact of heart rate.Heart,2002,88:470-474.

共引文献208

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部