Shell粉煤气化装置湿洗塔出口超温原因分析及超温影响 被引量:1

The cause analysis for exit over-temperature and its effect of wet washing tower on Shell powdered coal gasifying device
在线阅读 下载PDF
导出
摘要 目前国内大部分Shell煤气化工艺湿洗塔受操作温度、煤种、负荷影响,出口出现超温现象,本文通过分析Shell粉煤气化工艺湿洗塔出口超温原因,得出超温后将加快激冷气压缩机进口三通处腐蚀,必须通过优化操作温度,稳定适合运行的煤种及尽可能高负荷地运行,才能充分发挥出装置的潜能和优势。 In present, most wet washing tower of Shell powdered coal gasifying process appeared exit over - temperature that influenced by operation temperature, the kind of coal and loading. As the exit overtemperature cause analyzed, it was found that the enter three - way pipe corrosion was accelerated in quench gas compressor by over - temperature. So, the operation temperature should be optimized, the suitable kind of coal be stable and be running in high load as possible, the potency and superiority of the device could be functioning adequately.
作者 王飞
出处 《贵州化工》 2013年第1期12-14,共3页 Guizhou Chemical Industry
关键词 Shell粉煤气化工艺 合成气洗涤塔 出口超温 激冷气压缩机 三通腐蚀 Shell powdered coal gasifying process synthetic gas washing tower exit over - temperature quench gas compressor threeway pipe corrosion