本文通过分析热水饱和塔钢结构焊接中产生裂纹的原因 ,制定了相应的修复方案 ,成功地实施了 16MnR/30 4复合板与 30 4不锈钢的现场焊接。
Based of the analysis of the welding cracks of the hot and saturated tower,the relative repair procedures are made out and assessed.The spot welding practices of 16MnR/304 and 304 stainless steel were successfully carried out.