期刊文献+

APCO在围术期液体治疗反应性中的研究进展 被引量:2

Research progress on fluid responsiveness in perioperative period
暂未订购
导出
摘要 APCO(基于动脉压力波形的心排血量监测)对围术期液体治疗具有重要意义,是当今国内外研究的热点。通过对FloTrac/Vigileo系统在液体治疗反应性研究结果的分析,比较该系统与某些静态监测技术和其他动态监测技术的优劣,阐述了该系统在临床应用中的效果。其预测液体治疗反应性的最佳阈值尚需进一步研究。 Study on APCO is of great significance to the fluid therapy in perioperative period,which becomes a hot topic throughont the world.We analyzed the results of fluid responsiveness research by using Flo Trac/Vigileo system,compared the system with some static and other dynamic monitoring techniques,and expounded its effects in clinical practice.There needs more further research to find the threshold value of predicting fluid responsiveness.
作者 李季 陈萍
出处 《安徽医药》 CAS 2012年第10期1399-1401,共3页 Anhui Medical and Pharmaceutical Journal
关键词 基于动脉压力波形的心排血量监测 Flo Trac Vigileo系统 液体治疗反应性 APCO Flo Trac/Vigileo system fluid responsiveness
  • 相关文献

参考文献22

  • 1魏海燕,史宏伟,鲍红光.动脉压力波形分析技术在急性等容血液稀释中的应用[J].临床麻醉学杂志,2009,25(10):863-865. 被引量:12
  • 2Eleftheriadis S,Galatoudis Z,Didilis Z. Variations in arterial blood pressure are associated with parallel changes in FlowTrac/Vigileo(R)derived cardiac output measurements:a prospective comparison study[J].Critical Care,2009,(06):179-183.
  • 3Fredteic M,Jean LT. Using heart-lung interactions to assess fluid responsiveness during mechanical ventilation[J].Critical Care,2000,(05):282-289.
  • 4Biais M,Nouette-Gaulain K,Cottenceau V. Uncalibrated pulse contour-derived stroke volume variation predicts fluid responsiveness in mechanically ventilated patients undergoing liver transplantation[J].British Journal of Anaesthesia,2008,(06):761-768.doi:10.1093/bja/aen277.
  • 5Berkenstadt H,Margalit N,Hadani M. Stroke volume variation as a predictor of fluid responsiveness in patients undergoing brain surgery[J].Anesthesia and Analgesia,2001,(04):984-989.
  • 6Kumar A,Anal R,Bunnell E. Pulmonary artery occlusion pressure and central venous pressure fail to predict ventricular filling volume,cardiac performance,or the response to volume infusion in normal subjects[J].Critical Care Medicine,2004,(01):691-699.
  • 7Osman D,Ridel C,Ray P. Cardiac filling pressures are not appropriate to predict hemodynamic response to volume challenge[J].Critical Care Medicine,2007,(01):64-68.
  • 8Squara P,Bennett D,Perret C. Pulmonary artery catheter:does the problem lie in the users[J].Chest,2002,(06):2009-2015.
  • 9Hofer CK,Müller SM,Furrer L. Stroke volume and pulse pressure variation for prediction of fluid responsiveness in patients undergoing of-pump coronary artery bypass grafting[J].Chest,2005,(02):848-854.
  • 10Reuter DA,Felbinger TW,Schmidt C. Stroke volume variations for assessment of cardiac responsiveness to volume loading in mechanically ventilated patients after cardiac surgery[J].Intensive Care Medicine,2002,(04):392-398.doi:10.1007/s00134-002-1211-z.

二级参考文献9

  • 1王惠枢,张小霓.急性等容血液稀释对心脏的影响[J].医学综述,2006,12(21):1310-1312. 被引量:8
  • 2王燕,罗志刚,曾高峰.急性等容血液稀释在冠心病患者非心脏手术中可行性分析[J].中国动脉硬化杂志,2007,15(2):141-144. 被引量:4
  • 3Licker M, Ellenberger C, Sierra J,et al. Cardioprotective effects of acute normovolemic hemodilution in patients undergoing coronary artery bypass surgery. Chest,2005,128:838-847.
  • 4Casati V, Benussi S, Sandrelli L, et al. Intraoperative moderate acute normovolemic hemodilution associated with a comprehensive blood-sparing protocol in off-pump coronary surgery. Anesth Analg, 2004,98:1217-1223.
  • 5Cannesson M, Attof Y, Rosamel P, et al. Comparison of FloTrac cardiac output monitoring system in patients undergoing coronary artery bypass grafting with pulmonary artery cardiac output measurements. Eur J Anaesthesiol,2007,24:832-839.
  • 6Hofer CK,Senn A, Weibel L, et al. Assessment of stroke volume variation for prediction fluid responsiveness using the modified Flo-Trac and PiCCOplussystem. Crit Care, 2008; 12: R82.
  • 7Biais M, Nouette-Gaulain K, Cottenceau V, et al. Uncarlibrated pulse eontour-derived stroke volume variation predicts fluid responsiveness in mechanically ventilated patients undergoing liver transplantation. Br J Anaesth, 2008,101 : 761-768.
  • 8Marx G, Cope T, McCrossan L, et al. Assessing fluid responsiveness by stroke volume variation in mechanically ventilated patients with severe sepsis Eur J Anaesth,2004,21:132-138.
  • 9刘先义,夏正远,詹丽英,夏中元,罗涛,王昕.急性等容性血液稀释对心肌缺血再灌注损伤的保护作用[J].临床麻醉学杂志,2002,18(1):33-35. 被引量:6

共引文献11

同被引文献13

引证文献2

二级引证文献4

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部