期刊文献+

原子吸收光谱法测定活性污泥中Cu、Zn、Pb、Cd、Ni 被引量:6

Determination of Cu,Zn,Pb,Cd and Ni in Activated Sludge by Atomic Absorption Spectrometry
原文传递
导出
摘要 采用微波消解技术消解城市污水处理厂污泥样品,用火焰原子吸收光谱法测定Cu、Zn,石墨炉原子吸收光谱法测定Pb、Cd、Ni。通过测定国家标准参考物质和加标回收试验,对方法进行了验证,方法的精密度和准确度均能满足污泥环境样品的测试要求。在试验条件下,测定样品中Cu、Zn、Pb、Cd、Ni的加标回收率在95.2%~103%之间,相对标准偏差<3%。 Samples of activated sludge were digested by microwave, copper and zinc were determined by flame atomic absorption spectrometry, and lead, cadmium and nickel were determined by graphite furnace atomic absorption spectrometry. The method was validated by the recoveries of standard additions and standard material. The precision and accuracy of the method could meet the testing require- ment for sludge samples. Under the experimental conditions, the recovery rates of copper, zinc, lead, cadmium and nickel in the samples were in the range of 95.2% to 103%, and the RSDs were less than 3%.
出处 《中国给水排水》 CAS CSCD 北大核心 2013年第4期91-93,共3页 China Water & Wastewater
关键词 微波消解 原子吸收 污泥 重金属 microwave digestion atomic absorption sludge heavy metal
  • 相关文献

参考文献1

  • 1CJ/T 221-2005.城市污水处理厂污泥检验方法[S]..2005

同被引文献50

引证文献6

二级引证文献28

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部