摘要 Accurate attenuation correction is required in dedicated breast PET imaging systems for image artifact removal and quantitative studies. In this study, a method using only emission data based on consistency conditions is proposed for attenuation correction in breast PET imaging systems. The consistency conditions are exploited to evaluate the accuracy of the estimated attenuation distribution and find the appropriate parameters that yield the most consistent attenuation distribution with the measured emission data. We have proved the validity of the method with experimental investigations and single-patient studies using a dedicated breast PET. The results show that the method is capable of accurately estimating the attenuation distribution of a uniform attenuator from the experimental data with various relatively low activities. The results also show that in single-patient studies, the method is robust for the irregular boundary of breast tissue and provides a distinct improvement in image quality. Accurate attenuation correction is required in dedicated breast PET imaging systems for image artifact removal and quantitative studies. In this study, a method using only emission data based on consistency conditions is proposed for attenuation correction in breast PET imaging systems. The consistency conditions are exploited to evaluate the accuracy of the estimated attenuation distribution and find the appropriate parameters that yield the most consistent attenuation distribution with the measured emission data. We have proved the validity of the method with experimental investigations and single-patient studies using a dedicated breast PET. The results show that the method is capable of accurately estimating the attenuation distribution of a uniform attenuator from the experimental data with various relatively low activities. The results also show that in single-patient studies, the method is robust for the irregular boundary of breast tissue and provides a distinct improvement in image quality.
出处 《Chinese Physics C》 SCIE CAS CSCD 2013年第1期138-143,共6页 中国物理C(英文版)
基金 Supported by National Natural Science Foundation of China(81101070)
关键词 attenuation correction breast PET consistency conditions attenuation correction, breast PET, consistency conditions
  • 相关文献

参考文献28

  • 1Raylman R R, Majewski S, Wojcik R et al. Medical Physics, 2000, 24:1943.
  • 2Berg W A, Weinberg I N, Narayanan D et al. The Breast Jour- nal, 2006, 12:309.
  • 3Abreu M, Aguiar D, Albuquerque E et al. Nuclear Instruments and Methods in Physics Research, A, 2007, 571:81.
  • 4Avril N, Schelling M, Dose Jet al. Journal of Clinical Oncology, 2000, 18:3495.
  • 5WU Y, YANG K, Packard Net al. Physics in Medicine and Biology, 2009, 54:4273.
  • 6Zaidi H and Hasegawa B. Journal of Nuclear Medicine, 2003, 44:291.
  • 7Bailey D L. European Journal of Nuclear Medicine and Molec- ular Imaging, 1998, 25:774.
  • 8Kinahan P, Townsend D W, Beyer T et al. Medical Physics, 1998, 25:2046.
  • 9Beyer T, Townsend D W, Brun T et al. Journal of Nuclear Medicine, 2000, 41:1369.
  • 10Soriano A, Gonzlezb A, Orero A et al. NIMA_4th Inter- national Conference on Imaging Techniques in Subatomic Physics. Astrophysics, Medicine: Biology and Industry, 2010, 648:675.

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部