期刊文献+

不同脉冲高强度聚焦超声辐照方式损伤离体灌注猪肝的实验研究 被引量:3

Effect of ablations by pulsed versus continuous high-intensity focused ultrasound on isolated perfused porcine liver
暂未订购
导出
摘要 目的比较不同脉冲高强度聚焦超声(HIFU)辐照方式损伤离体灌注猪肝靶区临近含较大血管时的损伤情况,为临床应用提供依据。方法建立离体猪肝经肝动脉和门静脉的体外循环灌注模型,在B超引导下选择直径为4 mm血管,于血管方向离管壁3 mm位置给予相同剂量PHIFU辐照。实验组选择脉冲波,对照组用连续波,辐照结束后观察声通道血管及靶区损伤情况,并取血管与靶区处组织送病理检查。结果 PHIFU相同剂量辐照声通道内含4 mm大血管后,实验组和对照组的声通道血管均未见损伤,两组凝固性坏死体积比较存在差异(P<0.05),实验组坏死体积大于对照组。声通道血管进行HE染色、血管弹力纤维和胶原纤维染色显示没有损伤,实验组和对照组没有差别(P>0.05)。结论当靶区临近含有较大血管时,脉冲辐照能够提高HIFU治疗效率,有效的形成损伤,且不会损伤血管。 Objective To compare the effect of ablations with pulsed and continuous high-intensity focused ultrasound (HIFU) on the target area containing large blood vessels in isolated perfused porcine liver. Methods An isolated perfused liver model was established by perfusing the isolated porcine liver with autologous blood through the portal vein and hepatic artery using an cardiopulmonary bypass machine. With B-mode ultrasound guidance, a blood vessel about 4 mm in diameter was selected, and pulsed and continuous HIFU ablation at the same dose was delivered along the blood vessel at 3 mm to the vascular wall. After the ablation, the damages of the blood vessels as the acoustic channel and the target area were inspected, and the tissues at the interface of target volume and blood vessels were sampled for pathological examination. Results Neither pulsed nor continuous HIFU caused noticeable injuries of the acoustic channel vessels, but the volume of necrotic tissues in the target area differed significantly between the two groups (P〈0.05). HE staining and vessel staining did not show any injuries of the blood vessels in the pathway of ultrasound ablation in neither of the groups (P〉0.05). Conclusions When the target area contains large blood vessels in the pathway of ultrasound ablation, pulsed HIFU can have better therapeutic efficiency to effectively induce tissue damages without affecting the blood vessels.
出处 《南方医科大学学报》 CAS CSCD 北大核心 2013年第2期230-234,共5页 Journal of Southern Medical University
基金 国家重点基础研究发展计划973计划(2011CB707900) 国家自然科学基金重点项目(30830040) 国家自然科学基金面上项目(30970827)~~
关键词 脉冲高强度聚焦超声 离体猪肝 灌注模型 血管 pulsed high-intensity focused ultrasound isolated porcine liver perfusion model blood vessels
  • 相关文献

参考文献8

二级参考文献53

共引文献66

同被引文献23

  • 1刘春梅,陈锦云,柯丹,李崇雁,徐杰,雷令,李发琪.脉冲高强度聚焦超声联合微泡非热损伤兔肝VX2移植瘤的病理观察[J].中国超声医学杂志,2007,23(11):806-809. 被引量:9
  • 2Frenkel V,Ethefington A,Greene M,et al.Delivery of liposomal doxorubicin(Doxil) in a breast cancer tumor model:investigation of po- tential enhancement by pulsed-high intensity focused ultrasound expo- sure[J].Academic Radiology, 2006,13 ( 4 ) : 469-479.
  • 3Min JP,Young-sun K,Jehoon Y,et al.Pulsed high-intensity focusedultrasound therapy enhances targeted delivery of cetuximab to colon cancer xenograft model in mice[J].Ultrasound in Medicine & Biology, 2013,39(2) : 292-299.
  • 4Wang S,Shin IS,Hancock H,et al.Pulsed high intensity focused ultrasound increases penetration and therapeutic efficacy of monoclonal antibodies in murine xenograft tumors[J].Joumal of Controlled Release Official Journal of the Controlled Release Society,2012,162( 1 ):218- 224.
  • 5Hwang JH,Zhou Y ,Warren C, et al.Targeted venous occlusion us- ing pulsed high-intensity focused ultrasound[J].IEEE Trans Biomed Eng, 2010,57(1) :37-40.
  • 6Huber PE,Mann MJ,Melo LG,et al. Focused uhrasound(HIFU) induces localized enhancement of reporter gene expression in rabbit carotid artery[J].Gene Therapy,2003,10(18) : 1600-1607.
  • 7Lafon C,Khokhlova VA,Kaczkowski PJ,et al.Use of a bovine eye lens for observation of HIFU-induced lesions in real-time[J].Ultrasound in Medicine & Biology,2006,32(11) : 1731-1741.
  • 8Melodelima D, Chapelon JY, Theillre Y, et al.Combination of thermal and cavitation effects to generate deep lesions with an endo- cavitary applicator using a plane transducer:ex vivo studies[J].Ultra- sound in Medicine & Biology,2004,30(1) : 103-111.
  • 9Burke CW,Klibanov AL,Sheehan JP,et al.Inhibition of glioma growth by mierobubble activation in a subcutaneous model using low duty cycle ultrasound without significant heating[J].Journal of Neuro- surgery,2011,114(6) : 1654-1661.
  • 10Yang FY,Chiu WH,Liu SH,et al.Funetional changes in arteries induced by pulsed high-imensity foeused ultrasound[J].Ultrasonics Ferroeleetrics & Frequency Control IEEE Transactions on,2009,56 ( 12 ) : 2643-2649.