期刊文献+

Quantitation of bivalirudin,a novel anticoagulant peptide,in human plasma by LC-MS/MS:Method development,validation and application to pharmacokinetics 被引量:2

Quantitation of bivalirudin,a novel anticoagulant peptide,in human plasma by LC-MS/MS:Method development,validation and application to pharmacokinetics
暂未订购
导出
摘要 A rapid and sensitive method based on liquid chromatographtandem mass spectrometry (LC-MS/MS) for the determination of a novel anticoagulant peptide bivalirudin in human plasma has been developed and validated. Plasma samples were precipitated protein with acetonitrile and reextracted with dichloromethane, after which the analyte and triptorelin as an internal standard (IS) were separated on a 300SB-Cl8 column (150 mm x 4.6 mm i.d., 5 gm particle size) using 0.1% formic acid:methanol (45:55, v/v) as mobile phase. The triple-quadrupole mass spectrometer, equipped with electrospray ionization (ESI) interface, was operated in the positive ion mode, and the multiplereaction monitoring (MRM) transitions of bivalirudin and IS were at m/z 1091.0-650.4 and m/z656.5 - 249.3, respectively. The lower limit of quantification (LLOQ) was 1 ng/mL for 100 ng/mL plasma sample and the assay was linear over the concentration range 1 1000 ng/mL. The accuracy was within a range from -0.4% to 0.5% in terms of relative error (RE) and the intra- and inter-day precisions in terms of relative standard deviation (RSD) were 〈2.92 and 〈 3.36, respectively. The method was successfully applied to a pharmacokinetic study involving intravenous administration of bivalirudin (0.5 mg/kg) to Chinese volunteers. A rapid and sensitive method based on liquid chromatographtandem mass spectrometry (LC-MS/MS) for the determination of a novel anticoagulant peptide bivalirudin in human plasma has been developed and validated. Plasma samples were precipitated protein with acetonitrile and reextracted with dichloromethane, after which the analyte and triptorelin as an internal standard (IS) were separated on a 300SB-Cl8 column (150 mm x 4.6 mm i.d., 5 gm particle size) using 0.1% formic acid:methanol (45:55, v/v) as mobile phase. The triple-quadrupole mass spectrometer, equipped with electrospray ionization (ESI) interface, was operated in the positive ion mode, and the multiplereaction monitoring (MRM) transitions of bivalirudin and IS were at m/z 1091.0-650.4 and m/z656.5 - 249.3, respectively. The lower limit of quantification (LLOQ) was 1 ng/mL for 100 ng/mL plasma sample and the assay was linear over the concentration range 1 1000 ng/mL. The accuracy was within a range from -0.4% to 0.5% in terms of relative error (RE) and the intra- and inter-day precisions in terms of relative standard deviation (RSD) were 〈2.92 and 〈 3.36, respectively. The method was successfully applied to a pharmacokinetic study involving intravenous administration of bivalirudin (0.5 mg/kg) to Chinese volunteers.
出处 《Journal of Pharmaceutical Analysis》 SCIE CAS 2013年第1期1-8,共8页 药物分析学报(英文版)
基金 the National Natural Science Foundation (30973587) the China Postdoctoral Science Foundation (20110491328) the National Natural Science Funds for Young Scholar (81102383)for financial support
关键词 BIVALIRUDIN LC-MS/MS PHARMACOKINETICS Human plasma ANTICOAGULANT Bivalirudin LC-MS/MS Pharmacokinetics Human plasma Anticoagulant
  • 相关文献

参考文献1

二级参考文献2

  • 1卢晓阳,申屠建中,陈志根,黄明珠,周慧丽,郑国钢.液质联用测定血清中地氯雷他定及人体药动学研究[J].浙江大学学报(医学版),2005,34(4):372-374. 被引量:3
  • 2A Solans,I Izquierdo,E Donado. Pharmacokinetic and safety profile of rupatadine when coadministered with azithromycin at steady-state levels:a randomized,open-label,two-way,crossover,Phase Ⅰ study[J].Clinical Therapeutics,2009,(09):1639-1650.

共引文献4

同被引文献4

引证文献2

二级引证文献4

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部