期刊文献+

符合线路SPECT显像原理及其应用 被引量:12

Principle and application of SPECT with coincidence
暂未订购
导出
摘要 符合线路断层显像主要由可变角双探头SPECT系统、符合探测线路和衰减校正等组成。该设备不需要笨重的铅准直器,而是利用符合探测技术由成对的探测器装置接收湮没辐射产生的2个方向相反(成180o)能量相等(511keV)γ光子,经计算机处理,重建而获得各种参数和断层影像,从而对病变做出定性或定量诊断。符合线路SPECT的临床应用价值已得到临床肯定,这无疑对我国正电子成像事业发展具有重大的推动作用。本文对医用核子仪器尤其是近年来在国内外广泛应用的双和/或三探头符合线路SPECT显像的工作原理和特点及临床应用进行了综述。 Tomography with coincidence is composed of variable-angle dual and /or triple-head SPECT system, coincidence detection circuit and attenuation correction (AC). The imaging principles of coincidence detection (CD) without bulky and cumbersome lead-collimator detected two 511keV gamma photons (180 o direction) in annihilation by use of coincidence detection techniques, and acquired various parameters and section imaging to diagnose in the small lesion qualitatively and quantitatively through computer processing and reconstruction. The clinical application value and the imaging quality obtained from CD have been already confirmed. It is no doubt for propelling the development of our national positron imaging working to possess very important significance. In this paper, we describe the principle, properties and clinical application of dual and/or triple-head tomography with coincidence, one of the nuclear medicine imaging instruments, which has been recently widely used in our country.
作者 王荣福
出处 《中国医学装备》 2013年第1期52-55,共4页 China Medical Equipment
基金 国家重大科学仪器设备开发专项(2011YQ03011409)"基于多模态分子影像技术的新型肿瘤新生血管靶向显像剂及治疗药物的在体评价系统研究" 国家自然科学基金(81071183)"核素靶向示踪肿瘤新生血管作用位点研究"国家自然科学基金(30870729)"靶向肿瘤血管多肽显像与治疗实验研究" 教育部放射性药物重点实验室开放课题基金(120121)"新型肿瘤血管靶向示踪药物99Tcm-RRL的制备及体内显像的实验研究"
关键词 核子仪器 符合探测 放射性核素显像 符合线路断层显像 湮没辐射 Nuclear medicine instrumentation Coincidence detection Radionuclide imaging Tomography with coincidence Annihilation
  • 相关文献

参考文献15

二级参考文献53

  • 1沃金善,诸骏仁,李志善,杨洪霞,陈绍亮,赵惠扬.门控与非门控心肌断层显像诊断价值的比较[J].中华核医学杂志,1995,15(4):253-253. 被引量:1
  • 2Schiepers C, Penninckx F, De Vadder N, et al. Contribution of PET in the diagnosis of recurrent colorectal cancer: comparison with conventional imaging. Eur J Surg Oncol, 1995, 21: 517-522.
  • 3Delbeke D. Oncological application of FDG PET imaging: brain tumors,colorectal cancer, lymphoma and melanoma. J Nucl Med, 1999, 40:591-603.
  • 4王荣福.肿瘤:^(18)F-DG PET代谢显像[J].国外医学(放射医学核医学分册),1997,21(3):106-110. 被引量:13
  • 5Stumpe KD, Urbinelli M, Steinert HC, et al. Whole-body positron emission tomography using fluorodeoxyglucose for staging of lymphoma: effectiveness and comparison with computed tomography. Eur J Nucl Med, 1998, 25: 721-728.
  • 6Jerusalem G, Beguin Y, Fassotte F, et al. Whole-body positron emission tomography using 18F-fluorodeoxyglucose for posttreatment evaluation in Hodgkin′s disease and non-Hodgkin′s lymphoma has higher diagnostic and prognostic value than classical compute
  • 7Okada J, Yoshikawa K, Itami M, et al. Positron emission tomograhpy using fluorine-18-fluorodeoxyglucose in malignant lyphoma: a comparison with proliferative activity. J Nucl Med, 1992, 33: 325-329.
  • 8Zinzani PL, Magagnoli M, Chierichetti F, et al. The role of positron emission tomography (PET) in the management of lymphoma patients. Ann Oncol, 1999, 10: 1181-1184.
  • 9Matthies A, Hickeson M, Cuchiara A, et al. Dual time point 18F-FDG PET for the evaluation of pulmonary nodules. J Nucl Med, 2002, 43: 871-875.
  • 10Matthies A, Hickeson M, Cuchiara A, et al. Dual time point 18FFDG PET for the evaluation of pulmonary nodules. J Nucl Med, 2002, 43:871 - 875.

共引文献67

同被引文献105

引证文献12

二级引证文献27

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...