透析液电导率测量仪的研究 被引量:1

Research on the Conductivity Measuring Instrument for Dialysate
在线阅读 下载PDF
导出
摘要 根据透析液的特点,采用频率可调的双极性间歇脉冲方法,设计了一种透析液电导率测量仪。将该测量仪应用于电导率测量,同时对测量结果进行分段温度补偿。试验结果表明,双极性间歇脉冲法能够减弱极化效应和电容效应,有效提高测量精度。测量仪能够实现对透析液浓度的精确测量,可以广泛应用于血液透析机。 In accordance with the characteristics of dialysate, the method based on frequency adjustable bipolar intermittent pulse is proposed and an instrument for measuring the conductivity of dialysate is designed. This measuring instrument is applied into the measurement of conductivity; in addition, the piecewise temperature compensation is used for the measurement results. The experimental result shows that the method based on bipolar intermittent pulse can weaken the polarization effect and capacitance effect, and effectively improve the measurement accuracy, and the accurate measurement for dialysate concentration can be implemented by the measuring instrument. The instrument can be widely used in hemodialysis machines.
出处 《自动化仪表》 CAS 北大核心 2013年第1期64-68,共5页 Process Automation Instrumentation
基金 2010年珠海市产学研合作专项资金资助项目(编号:2010A0501006)
关键词 电导率 温度补偿 A D转换器 数据采集 标定 Conductivity Temperature compensation A/D conventer Data acquisition Calibration
  • 相关文献

参考文献8

二级参考文献60

  • 1冯仲科.全站仪特殊功能应用精度分析[J].工程勘察,1995,23(5):60-62. 被引量:11
  • 2刘松玉,查甫生,于小军.土的电阻率室内测试技术研究[J].工程地质学报,2006,14(2):216-222. 被引量:108
  • 3刘松玉,韩立华,杜延军.水泥土的电阻率特性与应用探讨[J].岩土工程学报,2006,28(11):1921-1926. 被引量:42
  • 4Doorenbos CJ, Bosma RJ, Lamberts PJ. Use of urea containing dialysate to avoid disequilibrium syndrome, enabling intensive dialysis treatment of a diabetic patient with renal failure and severe metformin induced lactic acidosis. Nephrol Dial transplant, 2001, 16:1303 - 1304.
  • 5Leehey DJ, Ing TS. Correction of hypercalcemia and hypophos- phatemia by hemodialysis using a conventional, calcium-containing dialysis soluteon enriched with phosphorus. Am J Kidney Dis, 1997, 29 : 288 - 290.
  • 6Sayarlioglu H, Erkoc R, Tuncer M, et al. Effects of low sodium dialysate in chronic hemodialysis patients: an echocardiographic study. Ren Fail, 2007, 29(2) : 143 -146.
  • 7Sarkar SR, Wystrychowski G, Zhu F, et al. Fluid dynamics during hemodialysis in relationship to sodium gradient between dialysate and plasma. ASAIO J, 2007, 53(3) : 339 -342.
  • 8Sahani MM, Daoud TM, Sam R, et al. Dialysis disequilibrium syndrome revisited. Hemodial Int, 2001, 5:92 -96.
  • 9Moret K, Hassell D, Kooman JP, et al. lonic mass balance and blood volume preservation during a high, standard, and individualized dialysate sodium concentrateion. Nephrol Dial Transplant, 2002, 17: 1463 - 1469.
  • 10Stiller S, Bonnie-Schorn E, Grassmann A, et al. A critical review of sodium profiling for hemodialysis. Semin Dial, 2001, 14:337 - 347.

共引文献69

同被引文献5

引证文献1

二级引证文献4

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部