3.0TMR三维时间飞跃法MR血管成像与DSA检出颅内动脉瘤的比较 被引量:32

Comparison of three dimensional time.of-flight MR angiography at 3. 0 T MR and DSA in the detection of intracranial aneurysms
原文传递
导出
摘要 目的以DSA为对照,研究3.0TMRVR重组三维时间飞跃法(3D-TOF)MRA诊断颅内动脉瘤的准确性。方法411例可疑颅内动脉瘤或其他脑血管疾病的患者在行DSA检查前进行3D-TOF-MRA检查,MRA检查后2周内进行DSA检查,以2D-DSA和VR-DSA结果作为金标准。42例患者被排除(6例因运动伪影被排除,36例因缺少VR-DSA数据被排除)。从每例患者有无动脉瘤、每枚动脉瘤和动脉瘤大小(〈3mm、3~5mm、〉5~10mm、〉10mm)3方面评估VR3D.TOF-MRA对颅内动脉瘤诊断的准确性、敏感度和特异度。结果在最终入选的369例患者中,VR-DSA在246例患者中检测到306枚颅内动脉瘤,123例患者无动脉瘤;3D-TOF-MRA在249例患者中检测到311枚颅内动脉瘤,120例患者无动脉瘤。从患者方面评估,VR3D-TOF-MRA对颅内动脉瘤的诊断准确性、敏感度和特异度依次为97.6%(360/369)、99.2%(242/244)和94.4%(118/125);从动脉瘤方面评估,VR3D-TOF-MRA的诊断准确性、敏感度和特异度依次为98.3%(524/533)、99.3%(304/306)和96.1%(220/229);基于动脉瘤大小(〈3mm)的评估,VR3D-TOF-MRA的诊断准确性、敏感度和特异度依次为96.4%(214/222)、98.2%(112/114)和94.4%(102/108)。结论VR3D-TOF-MRA能准确诊断颅内动脉瘤,并可以作为一种无创、无辐射和无须对比剂的检查方法来替代DSA诊断和筛查颅内动脉瘤。 Objective To investigate the diagnostic accuracy of contrast-free three dimensional time-of-flight (3D-TOF-MRA) with VR at 3.0 T in the detection of intracranial aneurysms in a large cohort of patients prospectively. Methods Four hundred and eleven patients with suspected aneurysms and other cerebral vascular diseases received contrast-free 3D-TOF-MRA examinations at 3.0 T MRA 2 weeks prior to DSA examination. 2D-DSA and VR-DSA were regarded as the gold standard. Six patients were excluded because of motion artifacts,and 36 patients were excluded due to lack of VR-DSA data. Accuracy, sensitivity an specificity in detecting intraeranial anemysms were determined by patient-, aneurysm-, and aneurysm size- based ( 〈 3 mm, 3-5 ram, 〉 5-10 ram, 〉 10 mm) evaluations. Results In 369 enrolled patients, VR-DSA revealed 306 anem'ysms in 246 patients (66.7%) and no aneurysm in 123 patients; VR 3D-TOF- MRA revealed 311 aneurysms in 249 patients and no aneurysm in 120 patients. The patient-based evaluation of VR 3D-TOF-MRA at 3.0T yielded accuracy of 97.6% (360/369), sensitivity of 99. 2% (242/244), and specificity of 94. 4% (118/125) in the detection of intracranial aneurysms. The aneurysm-based evaluation yielded accuracy of 98.3% (524/533) , sensitivity of 99.3% ( 304/306 ), and specificity of 96. 1% (220/229). The evaluation based on aneurysm sizes ( 〈3 mm) yielded accuracy of 96.4% (214/222),sensitivity of 98.2% ( 112/114 ), and specificity of 94. 4% ( 102/108 ). Conclusion VR 3D-TOF-MRA at 3.0 T MR can detect intracranial aneurysms accurately and may replace DSA as a contrast-free, noninvasive and non-radiation-based modality for the diagnosis and screening of intraeranial aneurysms.
出处 《中华放射学杂志》 CAS CSCD 北大核心 2013年第1期49-54,共6页 Chinese Journal of Radiology
基金 国家自然科学基金资助项目(81771440)
关键词 颅内动脉瘤 磁共振成像 血管造影术 数字减影 对比研究 Intracranial aneurysm Magnetic resonance imaging Angiography, digitalsubtraction Comparative study
  • 相关文献

参考文献26

  • 1Yelthuis BK, Hinkel GJ, Ramos LM, et al. Subarachnoid hemorrhage: aneurysm detection and preoperative evaluation with CT angiography. Radiology, 1998,208 :423-430.
  • 2Anxionnat R,Bracard S,Ducrocq X,et al. Intracranial aneurysms:clinical value of 3D digital subtraction angiography in the therapeutic decision and endovascular treatment. Radiology, 2001, 218: 799-808.
  • 3Cloft HJ, Joseph GJ. Dion JE. Risk of cerebral angiography in patients with subarachnoid hemorrhage. cerebral aneurysm, and arteriovenous malformation: a meta-analysis. Stroke, 1999, 30: 317-320.
  • 4McKinney AM, Palmer CS, Truwit CL, et al. Detection of aneurysms by 64-seclioll multiderector CT angiography in patients acutely suspected of having an intracranial aneurysm and comparison with digital subtraction and 3D rotational angiography. AJNH Am J Neutoradiol ,2008 ,29 :594-602.
  • 5Jayaraman MV, Mayo-Smith WW, Tung GA, et al. Detection of intracranial aneurysms: multi-detector row CT angiography compared with DSA. Radiology ,2004 ,230 :510-518.
  • 6Korogi Y, Takahashi M, Katada K, et al. Iruracranial aneurysms: detection with three-dimensional CT angiography with volume rendering. Comparison with conventional angiographic and surgical findings. Radiology, 1999,211:497-506.
  • 7乐维婕,李明华,李文彬,方淳,李成州.颅颈部血管多层螺旋减影CTA与DSA的比较研究[J].介入放射学杂志,2007,16(5):307-311. 被引量:9
  • 8Yoon DY, Lim K J, Choi CS, et al. Detection and characterization of intracranial aneurysms with 16-channel muhidetector row CT angiography: a prospective comparison of volume-rendered images and digital subtraction angiography. AJNR Am J Neutoradiol, 2007,28:60-67.
  • 9Mnyusiwalla A, Aviv RI, Symons SP. Radiation dose from multidetector row CT imaging for acute stroke. Neuroradiology, 2009,51:635-640.
  • 10Atlas SW, Sheppard L, Goldberg HI, et al. Intracranial aneurysms : detection and characterization with MR angiography with use of an advanced postprocessing technique in a blinded-reader study. Radiology, 1997,203 : 807-814.

二级参考文献58

  • 1孙鹏,彭军,宋和凤.血管内支架成形术治疗外科高危的颈动脉狭窄[J].介入放射学杂志,2004,13(3):218-219. 被引量:6
  • 2沈君,梁碧玲,谢榜昆,张嵘,周翠屏,李洁婷,曾伟科,邱连葵,云文娟.64层螺旋CT头部血管减影成像技术初探[J].中山大学学报(医学科学版),2006,27(6):709-712. 被引量:11
  • 3Zhou B, Li MH, Wang W, et al. Three-dimensional volumerendering technique in the angiographie follow-up of cerebral aneurysms embolized with coils. J Neurosurg, 2010, 112: 674-680.
  • 4Kaufmann TJ, Huston J 3rd, Mandrekar JN, et al. Complications of diagnostic cerebral angiography: evaluation of 19826 consecutive patients. Radiology, 2007,243:812-819.
  • 5Tang PH, Hui F, Sitoh YY. Cerebral aneurysm detection with 3 T magnetic resonance angiography. Ann Aead Med Singapore, 2007.36 '.388-393.
  • 6Mende KA, Froehlich JM, yon Weymarn C, et al. Time-resolved, high-resolution contrast-enhancaed MR angiography of dialysis shunts using the CENTRA keyhole technique with parallel imaging. J Magn Reson Imaging, 2007,25:832-840.
  • 7Taschner CA, Gieseke J, Le Thuc V, et al. Cerebral arteriovenous malformation: time-resolved contrast-enhanced MR angiography with combination of parallel imaging, keyhole acquisition, and k-space sampling techniques at 1.5 T. Radiology, 2008,246:871-879.
  • 8Willinek WA, Hadizadeh DR, yon Falkenhausen M, et al. 4D time-resolved MR angiography with keyhole (4D-TRAK) : more than 60 times accelerated MRA using a combination of CENTRA, keyhole, and SENSE at 3.0 T. J Magn Reson Imaging, 2008,27: 1455-1460.
  • 9Korperich H, Gieseke J, Esdorn H, et al. Uhrafast time-resolved contrast-enhanced 3D pulmonary venous cardiovascular magnetic resonance angiography using SENSE combined with CENTRA- keyhole. J Cardiovase Magn Reson, 2007,9:77-87.
  • 10Hiratsuka Y, Miki H, Kiriyama I, et al. Diagnosis of unruptured intracranial aneurysms: 3 T MR angiography versus 64-channel multi-detector row CT angiography. Magn Reson Med Sci, 2008, 7:169-178.

共引文献45

同被引文献226

引证文献32

二级引证文献200