喜河水电站中孔工作闸门充压式水封改造 被引量:2

Rehabilitation of Pressurized Sealing for Middle-Outlet Service Gate,Xihe Hydropower Station
在线阅读 下载PDF
导出
摘要 针对喜河水电站中孔闸门在投运初期因充压式水封效果较差导致闸门漏水的现象,客观地分析了中孔闸门止水设计及安装环节存在的问题,提出了中孔工作闸门止水的改造方案。经运行验证:水封的改造是成功的。 Aiming at leakage from the middle-outlet gate due to the pressurized sealing with poor effect in the initial operation period of Xihe Hydropower Station, issues on design and installation of waterstop for the middle-outlet service gate of Xihe Hydropower Station are objectively analyzed as well as scheme for rehabilitation of the waterstop for the middle-outlet service gate is provided. The sealing rehabilitation is proved successful through its operation.
机构地区 喜河水力发电厂
出处 《西北水电》 2012年第6期94-96,100,共4页 Northwest Hydropower
关键词 工作闸门 水封 漏水 改造 优化 喜河水电站 service gate sealing water leakage rehabilitation optimization Xihe Hydropower Station