期刊文献+

对比三维超声VOCAL技术与CT评估兔肝脏体积 被引量:5

Measurement of rabbit's liver volume: Comparison of three-dimensional ultrasound with VOCAL technique and CT
暂未订购
导出
摘要 目的对比评估三维超声VOCAL技术和CT测量兔肝脏体积的准确性。方法分别采用三维超声VOCAL技术和CT测量30只兔肝脏体积,将测量结果与采用水浸法测得的肝脏实际体积值进行比较。结果兔肝脏体积的三维超声VOCAL测量值、CT测量值与实际值间两两比较差异均无统计学意义(P均>0.05)。VOCAL法与CT法的测量误差分别为8.40%±4.40%及6.68%±4.45%(P>0.05)。三维超声VOCAL法测得的兔肝脏体积与实际值高度相关(r2=0.880,Y=9.146+0.826 X,P<0.001)。结论三维超声VOCAL技术可以准确测量兔肝脏体积,为评估不规则脏器体积提供了新的方法。 Objective To explore the accuracy of three-dimensional ultrasound with virtual organ computed aided analysis (VOCAL) technique in assessment of rabbit's liver volume by comparison with CT. Methods Thirty rabbits' liver volume were calculated with VOCAL and CT, and then compared to actual volumes respectively. The actual liver volume was measured with immersion method. Results There was no statistical difference among results of VOCAL, CT and the actual volume (all P〉0.05). The error of the VOCAL and CT method was 8.40%±4.40% and 6.68%±4.45%, respectively. The correlation was good between VOCAL results and the actual volumes (r2=0.880, Y=9.146+0.826X, P〈0.001). Conclusion Three-dimensional ultrasound with VOCAL technique can measure the rabbit's liver volume accurately, therefore providing a new method for in vivo measurement of the volume of irregular organs.
出处 《中国医学影像技术》 CSCD 北大核心 2013年第1期11-14,共4页 Chinese Journal of Medical Imaging Technology
关键词 超声检查 三维 体积自动测量技术 肝脏 Ultrasonography, three-dimensional Virtual organ computer aided analysis Liver
  • 相关文献

参考文献11

  • 1Harada N, Shimada M, Yoshizumi T, et al. A simple and accurate formula to estimate left hepatic graft volume in living-donor adult liver transplantation. Transplantation, 2004,77 (10) : 1571- 1575.
  • 2Stapakis J, Stamm E, Townsend R, et al. Liver volume assessment by conventional vs. helical CT. Abdom Imaging, 1995, 20 (3) :209-210.
  • 3Grison A, Maschietto N, Reffo E, et al. Three-dimensional echocardiographic evaluation of right ventricular volume and function in pediatric patients : Validation of the technique. J Am Soc Echocardiogr, 2007,20(8): 921-929.
  • 4刘炜,蔡爱露,赵丹,郭淑香.三维超声容积自动测量技术评价胎儿小脑蚓部发育[J].中国医学影像技术,2008,24(11):1795-1798. 被引量:11
  • 5Raine-Fenning N, Campbell B, Collier J, et al. The reproducibility of endometrial volume acquisition and measurement with the VOCAl. imaging program. Ultrasound Obstet Gynecol, 2002, 19 (1) :69-75.
  • 6徐辉雄,徐作峰,吕明德,谢晓燕,刘丽,刘广健,黄蓓.三维超声容积自动测量技术的准确性及重复性研究[J].中国超声医学杂志,2003,19(3):232-236. 被引量:50
  • 7张剑,胡建群,夏泽.三维超声测量不规则物体体积的准确性[J].中国医学影像技术,2009,25(6):1099-1102. 被引量:16
  • 8童放,夏泽,夏炳兰,钱晓芹.不同旋转步长三维超声体积自动测量技术测量体积准确性的仿体实验研究[J].中国医学影像技术,2009,25(1):132-134. 被引量:9
  • 9Nawarantne S, Fabiny R, Brien JE, et al. Accuracy of volume measurement using helical CT. J Comput Assist Tomogr, 1997, 21 (3) :481-486.
  • 10Sakamoto S, Uemoto S, Urynkara K, et al. Graft size assessment and analysis of donors for living donor liver transplantation using right lobe. Transplantation, 2002,71(10):1407-1413.

二级参考文献46

共引文献92

同被引文献63

  • 1郭佑民,张少娟,杨健,李洪伦,汪军峰,陈敏.CT动脉造影对肺动脉栓塞诊断价值的Meta分析[J].中华放射学杂志,2004,38(7):706-710. 被引量:15
  • 2付京波,王霄英,李龙,黄柳明,贾钧.MR对离体肝脏体积测量的实验研究[J].中国医学影像技术,2006,22(1):48-50. 被引量:5
  • 3潘克华,郑祥武,董丽卿,吴恩福.多层螺旋CT肝脏容积测量及不同测量方法对比应用[J].医学影像学杂志,2007,17(3):269-272. 被引量:2
  • 4Cerda C, Perez-Ayuso RM, Riquelme A, et al. Nonalcoholic fatty liver disease in women with polycystic ovary syndrome[J]. J Hepatol, 2007,47:412-417.
  • 5Hollinrake E, Abreu A, Maifeld M, et al. Increased risk of depressive disorders in women with polycystic ovary syndrome[J]. Fertil Steril,2007,87:1369-1376.
  • 6Rotterdam ESHRE/ASRM-Sponsored PCOS workshop group. Revised 2003 consensus on diagnostic criteria and long-term health risks related to polyeystic ovary syndrome (PCOS) [J]. Hum Reprod,2004,19:41-47.
  • 7Adams J,Franks S, Poison DW, et al. Multifollicular ovaries clinical and endocrine features and response to pulsatile gonadotropin releasing hormone [J].Lancet, 1985, 2: 1375-1379.
  • 8Raine-Fenning NJ, Campbell BK, Clewes JS, et al. The interobserver reliability of ovarian volume measurement is improved with three-dimensional ultrasound, but dependent upon technique[J]. Ultrasound Med Biol,2003,29:1685 1690.
  • 9Raine-Fenning N,Jayaprakasan K, Clewes J, et al. SonoAVC: a novel method of automatic volume calculation[J].Ultrasound Obstet Gynecol,2008,31:691-696.
  • 10Rodriguez Fuentes A, Herngndez J, Garcia-Guzman R, et al. Prospective evaluation of automated follicle monitoring in 58 in vitro fertilization cycles: follicular volume as a new indicator of oocyte maturity[J].Fertil Steril,2010,93: 616-620.

引证文献5

二级引证文献35

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部