期刊文献+

消毒液浸泡对牙科石膏模型尺寸的影响

The effect of disinfectant soaking on dental gypsum model size
原文传递
导出
摘要 目的:探讨消毒液浸泡3种牙科石膏模型后对其尺寸稳定性的影响。方法:用临床常用的3种不同类型石膏(Ⅲ型、Ⅳ型、Ⅴ型)制作50 mm×15 mm×10 mm 3组共24个试件。1 h后脱模,静置24 h后,用数显卡尺测量石膏模型尺寸。以蒸馏水浸泡作为对照,设戊二醛消毒剂、麦瑞斯消毒液浸泡为实验组,浸泡0.5 h取出,静置0.5、1、2、24 h后,用数显卡尺测量模型尺寸。采用SPSS10.0软件包对数据进行统计学分析。结果:浸泡前,3组石膏模型长度分别为(50.073±0.017)mm、(50.048±0.015)mm和(50.027±0.015)mm;浸泡后,各实验组、各时间点的模型尺寸基本无变化,石膏模型的尺寸变化小于0.01%。结论:消毒液浸泡对牙科石膏模型尺寸基本无影响。 PURPOSE: To study the influence of disinfectant soaking on the dimensional stability of three kinds of dental gypsum model. METHODS: Three commonly used gypsums ( type m , Iv, v type) in clinic were used to make 24 specimens for 50 mm×l5 mm×10 mm in size. One hour after release, the specimens were placed for 24 h. A digital caliper was used to measure the size of the gypsum model. Distilled water immersion was as used control, glutaraldehyde disinfectant and Metrix CaviCide disinfectant soaking were used for the experimental group. After soaking for 0.5h, the gypsum models were removed and placed for 0.5 h, 1 h, 2 h, 24 h. The size of the models was measured again using the same method. The data was analyzed with SPSS10.0 software package. RESULTS: The initial gypsum model length was (50.07_+0.017) mm, (50.048_+0.015) mm and (50.027_+0.015) mm. After soaking for different times, the size of the model changed little, and the dimensions changed less than 0.01%. CONCLUSION: The results show that disinfectant soaking has no significant effect on dental model dimensions. Supported by Research Fund of Science and Technology Commission of Shanghai Municipality (08DZ2271100,09411954700),Shanghai Leading Academic Discipline Project ($30206,T0202) and Foundation of Shanghai Municipal Health Bureau (2010268).
出处 《上海口腔医学》 CAS CSCD 北大核心 2012年第6期656-658,共3页 Shanghai Journal of Stomatology
基金 上海市科学技术委员会资助项目(08DZ2271100,09411954700) 上海市重点(特色)学科建设项目(T0202,S30206) 上海市卫生局项目(2010268)~~
关键词 石膏模型 戊二醛消毒剂 麦瑞斯消毒液 Gypsum model Glutaraldehyde disinfectant Metrix CaviCide disinfectant
  • 相关文献

参考文献11

二级参考文献32

  • 1尹美女,施更生,戴淑真.口腔科门诊院内感染的控制和管理[J].口腔医学,2004,24(3):150-150. 被引量:9
  • 2王海雪,周慧霞,左亚新.浅谈口腔门诊的感染管理[J].解放军护理杂志,2000,17(2):49-50. 被引量:64
  • 3顾斌,马轩祥.常用消毒方法灭活藻酸盐印模表面乙肝病毒的效果[J].中华老年口腔医学杂志,2005,3(4):216-219. 被引量:5
  • 4李新武,李秋丽,李涛,孙守宏,袁洽■.一种戊二醛复方消毒剂杀灭微生物效果观察[J].中华流行病学杂志,1996,17(5):292-295. 被引量:9
  • 5[2]Chaffee NR,Bailey JH,Sherrard DJ.Dimensional accuracy of improved dental stone and epoxy resin die materials.Part Ⅰ:Single die[J].J Prosthet Dent,1997,77(2):131 ~ 135
  • 6[4]Blair FM,Wassell RW.A survey of the methods of disinfection of dental impressions used in dental hospitals in the United Kingdom[J].Br Dent J.1996,25,180(10):369~ 375
  • 7[5]Council on Dental Materials,Instruments,and Equipment.Council on Dental Practice.Council on Dental Therapeutics.Infection control recommendations for the dental office and the dental laboratory[J].J Am Dent Assoc,1988,116(2):241 ~248
  • 8[6]Jones ML,Newcombe RG,Barry G,et al.A Reflex Plotter investigation into the dimensional stability of alginate impressions following disinfection by varying regimes employing 2.2 per cent glutaraldehyde[J].Br J Orthod,1988,15(3):185~192
  • 9[7]Matyas J,Dao N,Caputo AA.Effects of disinfectants on dimensional accuracy of impression materials[J].J Prosthet Dent,1990,64(1):25~ 31
  • 10[8]al-Omari WM,Jones JC,Wood DJ.The effect of disinfecting alginate and addition cured si[icone rubber impression materials on the physical properties of impressions and resultant casts[J].Eur J Prosthodont Restor Dent,1998,6(3):103~ 110

共引文献151

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部