期刊文献+

生物型假体在髋关节翻修术中的应用

Biological Prosthesis in Hip Revision
原文传递
导出
摘要 目的:通过资料分析了解生物型假体应用于髋关节翻修手术的研究进展。方法:收集并分析国内外最新的相关资料,总结生物型髋关节假体设计特点及其用于翻修手术的适应证、禁忌证、手术注意事项及其随访研究结果。结果:用于髋关节翻修的生物型假体目前仍以金属一聚乙烯或陶瓷一聚乙烯界面为主,金属一金属以及陶瓷一陶瓷等新型界面的临床效果尚需时间的考验。股骨骨量的评估是选择生物型假体翻修的主要参考指标。在髋关节翻修手术中,生物型假体表现出良好的早、中期疗效,长期随访研究报道较少。结论:生物型假体在髋关节翻修术中表现出良好的应用前景。 Objective:To comprehend the trend of biological prosthesis used in hip revision surgery by analyzing data. Methods:Some related information at home and abroad was collected and analyzed, designing features of biological hip prosthesis and their contraindication, indication and precautions in hip revision surgery were described. Follow - up study results were also analyzed. Results : Weight - bearing surface of biological prosthesis used in hip revision in clinical practice was still metal - polyethylene or ceramic - polyethylene inter- face. The clinical effect of new interface, such as the metal - metal and ceramic - ceramics, still needed further study. Assessment of the femur bone mass was the main reference of selected biological prosthesis. In hip revi- sion surgery, biological prosthesis presented a good early, mid -term efficacy. However, long -term follow - up studies had been less reported. Conclusions:Biological prosthesis used in hip revision surgery have a good prospects.
出处 《解剖与临床》 2012年第6期520-523,共4页 Anatomy and Clinics
关键词 生物型假体 髋关节置换术 翻修 Biological prosthesis Hip Hip arthroplasty Revision
  • 相关文献

参考文献35

  • 1Jackson J. Father of the modem hip replacement : Professor Sir John Charnley (1911 -82). J Med Biogr, 2011, 19(4) : 151 -156.
  • 2闫玉华,段湘慧.人工关节的研究现状和发展趋势[J].生物骨科材料与临床研究,2004,1(4):39-43. 被引量:22
  • 3Morscher EW. Hydroxyapatite coating of prostheses. J Bone Joint Surg Br, 1991,73(5) : 705 -706.
  • 4让昨天告诉今天:人工髋关节研究的学术与技术进展[J].中国组织工程研究与临床康复,2009,13(4):690-691. 被引量:8
  • 5Jafari SM, Bender B, Coyle C, et al. Do tantalum and titanium cups show similar results in revision hip arthroplasty? Clin Orthop Relat Res, 2010, 468(2) : 459 -465.
  • 6Fernandez - Fairen M, Murcia A, Blanco A, et al. Revision of failed total hip arthroplasty acetabular cups to porous tantalum components : a 5 - year follow - up study. J Arthroplasty, 2010, 25 (6) : 865 - 872.
  • 7Somers JF, Timperley A J, Norton M, et al. Block allografts in revi- sion total hip arthroplasty. J Arthroplasty, 2002, 17 (5) : 562 -568.
  • 8Khanuja HS, Vakil JJ, Goddard MS, et al. Cementless femoral fixa- tion in total hip arthroplasty. J Bone Joint Surg Am, 2011,93 (5) : 500 - 509.
  • 9Marshall AD, Mokris JG, Reitman RD, et al. Cementless titanium tapered -wedge femoral stem: 10 - to 15 - year follow - up. J Ar- throplasty, 2004, 19(5): 546-552.
  • 10LaPorte DM, Mont MA, Hungerford DS. Proximally porous - coated ingrowth prostheses: limits of use. Orthopedics, 1999, 22 ( 12 ) : 1154 -1160.

二级参考文献40

  • 1杨子彬,陆颂芳.生物医学工程[J].中华医学杂志,1994,74(12):778-778. 被引量:2
  • 2马忠泰,文立成,袁毓,柴卫兵,曹永平.H/G非骨水泥人工全髋关节的临床应用[J].中华骨科杂志,1996,16(5):271-274. 被引量:11
  • 3孙俊英,唐天驷,朱国良,洪天绿,董天华.巨孔表面全髋股骨头假体的无骨水泥置换术(附42例报告)[J].中华骨科杂志,1997,17(3):163-166. 被引量:8
  • 4[1]Noble PC. Bi omechanical Advances in Total Hip Replacement in Biomechanical in Orthopaedics(eds Niwa Perren SM, Hattori T)Tokyo Japan Springerverlag, 1992,46~75.
  • 5[2]Soballe K, Hansen ES, Brockstedt-Rasmussen H, et al.Tissue Ingrowthinw Titanium end Hydroxyapatite-Coated Implants during Stable and Unstable Mechanical Conditions Loaded Implants[J].J Orthop Res, 1992,10:265~299.
  • 6[3]Soballe K, Hansen en ES, Brockstedt-Rasmussen H, et al.ydroxyapatite Coating Converts Fibrouse Tissue to Bone Around Loaded Implants[J]. J Bone and Joint Surg(Br),1993, 75: 270~ 278.
  • 7[4]Aspenberg-P,Van-der-Vis-H,Migration, Particles, and Fluid Pressure. A Discussion of Cause of Prosthetic Loosening[J]. Clinic Orthop, 1998, Jul(852):75~80.
  • 8[5]Kenedy-JG, Grifen-DG, Sheehan-LJ.Effect of Acetabular Component Orientation on Recurrent Dsslocation Pelvic Osteolysis, Polyethylene Wear, and Component Migration[J].J. Arthroplasty, 1998, Aug13(5):530~534.
  • 9Schmalzried TJ, Berry DJ, Barrack RL, et al. Contemporary issues in total hip arthroplasty. Am J Orthop, 2001, 8:626 -632
  • 10Gurkan L, Wenz JF. Modular femoral implants for revision hip arthroplasty. Current Opinion in Orthopaedics, 2002,13:67-70

共引文献56

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部