BLADE技术在消除MRI膝关节运动伪影方面的应用 被引量:7

BLADE technology to eliminate MRI of knee joint motion artifacts
暂未订购
导出
摘要 目的探讨刀锋伪影校正(BLADE)技术在消除MRI膝关节运动伪影的应用价值。方法 32例膝关节常规MRI检查中出现运动伪影的患者,改用BLADE技术扫描(PD矢状位、T2矢状位),以是否能够清晰显示膝关节结构、半月板及交叉韧带为标准,与常规序列对比评估BLADE技术对消除膝关节运动伪影的应用价值。结果膝关节常规序列扫描中出现运动伪影,改用BLADE技术扫描后,图像运动伪影消除,图像质量明显改善。结论 BLADE技术对膝关节常规扫描中产生的运动伪影有明显的校正作用,可广泛用于产生运动伪影的膝关节MRI检查中。 Objective To investigate the value of the blade artifact correction (BLADE) technology in eliminating the knee joint motion artifacts in the MR examination. Methods 32 patients with motion artifacts in the knee conventional MR examination were added standard BLADE technology to scan (PD sagittal, T2 sagittal), compared with conventional sequence, assessed the value of the BLADE technology to eliminate motion artifacts of the knee with a standard of clear display of the structure of the knee, meniscus and cruciate ligament. Results Switching to BLADE technology scanning, the image motion artifacts produced in the knee conventional examination was disappeared, and the image quality was im proved significantly. Conclusion BLADE technology with significant role in correction the motion artifacts produced in the conventional scanning of the knee can be widely used to produce motion artifacts knee MRI examination.
出处 《医学影像学杂志》 2012年第12期2095-2097,共3页 Journal of Medical Imaging
关键词 膝关节 磁共振成像 伪影 刀锋伪影校正 Knee Magnetic resonance imaging Artifacts Blade artifact correction
  • 相关文献

参考文献5

二级参考文献40

  • 1秦文,于春水,李坤成.螺旋桨(PROPELLER)技术的原理及应用[J].医学影像学杂志,2005,15(10):912-915. 被引量:24
  • 2戈明媚,王秋良,刘志钦,刘晓林,廖玉珍,孙玮,孙楠,张英魁.MR螺旋桨扫描技术在消除伪影方面的临床应用[J].中华放射学杂志,2006,40(2):208-212. 被引量:37
  • 3李建伟.探讨扫描区域位置对MRI图像质量的影响[J].放射学实践,2006,21(4):403-404. 被引量:3
  • 4Pipe JG, Farthing VG, Forbes KP. Multishot Diffusion-weighted FSE Using PROPEIIER MRI[J].Magn Reson Med, 2002,47(1):42-52.
  • 5Glover GH, Pauly JM. Projection Reconstruction Techniques for Reduction Of Motion Effects in MR/ [J].Magn Reson Med,1992,28 (3):275-289.
  • 6Forbes KP, Pipe JG, Bird CR, et al. PROPELLER MRI:Clinical Test- ing of a Novel Technique for Quantification and Compensation of Head Motion [J]. Magn Resort Med, 2001, 14(3):215-222.
  • 7Pipe JG. Motion Correction with PROPELLER MRI: Application to Head Motion and Free-breathing cardiac Imaging [J]. Magn Reson Med, 1999,42(10): 963-969.
  • 8Forbes KP, Pipe JG, KariS JP, et al. Brain Imaging In the Unsedated Pediatric Patient: Comparison of Periodically Rotated Overlapping Parallel Lines with Enhanced Reconstruction and Singleshot Fast Spin-echo Sequences[J]. AJNR, 2003,24(8):795-798.
  • 9Nishimura DG,Irarrazabal P,Meyer CH.A velocity k-space analysis of flow effects in echo-planar and spiral imaging.Magn Reson Med,1995,33:549-556.
  • 10Glover GH,Pauly JM.Projection reconstruction techniques for reduction of motion effects in MRI.Magn Reson Med,1992,28:275-289.

共引文献71

同被引文献61

引证文献7

二级引证文献34

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部