期刊文献+

污垢对高压加热器端差的影响研究

Study on the Fouling affecting the Terminal Temperature Difference of High-pressure Heater
在线阅读 下载PDF
导出
摘要 高压加热器是汽轮机的重要辅助设备之一,其性能直接影响机组运行的经济性。高压加热器长期运行后,将在管子的内外表面上形成以氧化铁为主的污垢,积聚的污垢将降低换热管的传热效果,也会使加热器的端差增大。现以660MW机组卧式高加为研究对象,以传热学理论为基础,分析了污垢的形成机理及对换热设备产生的危害,定量计算了污垢热阻对传热系数和端差的影响,对加热器的正常运行有一定参考价值。 HP heater is one of the most important turbine auxiliary equipment, whose operating performance would directly affect the economy of the entire power unit. There are much iron oxide-based fouling both on the inner external surfaces of the condenser tubes after long-term operation, which will reduce the effect of heat transfer and increase the terminal temperature difference. Now the formation mechanism of the fouling and its hazards against the heat exchange equipment have been analyzed and a quantitative calculation of the effect of fouling resistance against heat transfer coefficient and terminal temperature difference based on the heat transfer theory has been carried out taking a 660 MW horizontal power unit as a study example, which is valuable to the normal operation of a condenser.
出处 《电站辅机》 2012年第4期8-12,共5页 Power Station Auxiliary Equipment
关键词 高压加热器 污垢 热阻 传热系数 端差 计算 机理 影响 high pressure heater fouling thermal resistance heat transfer coefficient terminal temperature difference calculation mechanism effect
  • 相关文献

参考文献2

二级参考文献5

共引文献7

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部