期刊文献+

Study on parameters influencing analytical performance of laser-induced breakdown spectroscopy 被引量:2

Study on parameters influencing analytical performance of laser-induced breakdown spectroscopy
原文传递
导出
摘要 Lens-to-sample distances, delay time, atmospheric condition, laser pulse energy, etc. had obvious effects on the analytical performance of laser-induced breakdown spectroscopy. In this paper, these parameters are investigated in greater detail and we will explain how they have influences on the analytical performance. The results show that the focal plane under the sample surface can improve precision and detection limit, and the delay time should be decided according to sensitivity and accuracy. Spectral line intensity is stronger in argon than helium, nitrogen and air gas environment. Pulse energy should exceed energy threshold (about 50 m J) which can generate plasma, and the energy should not exceed about 300 mJ to avoid plasma shielding. Under optimum parameters, concentration relative standard deviation of C, Si, Mn, P, S, Ni, and Cr for low-alloyed steel (sample number 11278) which were measured 11 times is 2.37%, 2.18%, 2.23%, 7.8%, 9.34%, 1.92%, and 2.13%, respectively. And the detection limit of C, Si, Mn, P, S, Ni, and Cr for pure steel is 0.0045%, 0.0072%, 0.0069%, 0.0027%, 0.0024%, 0.0047%, and 0.0024%, respectively. Lens-to-sample distances, delay time, atmospheric condition, laser pulse energy, etc. had obvious effects on the analytical performance of laser-induced breakdown spectroscopy. In this paper, these parameters are investigated in greater detail and we will explain how they have influences on the analytical performance. The results show that the focal plane under the sample surface can improve precision and detection limit, and the delay time should be decided according to sensitivity and accuracy. Spectral line intensity is stronger in argon than helium, nitrogen and air gas environment. Pulse energy should exceed energy threshold (about 50 m J) which can generate plasma, and the energy should not exceed about 300 mJ to avoid plasma shielding. Under optimum parameters, concentration relative standard deviation of C, Si, Mn, P, S, Ni, and Cr for low-alloyed steel (sample number 11278) which were measured 11 times is 2.37%, 2.18%, 2.23%, 7.8%, 9.34%, 1.92%, and 2.13%, respectively. And the detection limit of C, Si, Mn, P, S, Ni, and Cr for pure steel is 0.0045%, 0.0072%, 0.0069%, 0.0027%, 0.0024%, 0.0047%, and 0.0024%, respectively.
出处 《Frontiers of physics》 SCIE CSCD 2012年第6期714-720,共7页 物理学前沿(英文版)
关键词 laser-induced breakdown spectroscopy (LIBS) analytical performance plasma diagno- sis plasma shielding laser-induced breakdown spectroscopy (LIBS), analytical performance, plasma diagno- sis, plasma shielding
  • 相关文献

参考文献23

  • 1V. Bulatov, L. Xu, and 1. Schechter, Anal. Chem., 1996, 68(17): 2966.
  • 2J. A. Aguilera and C. Aragon, Spectrochim. Acta B, 2004, 59: 1861.
  • 3R. Noll, H. Bette, A. Brysch, M. Kraushaar, I. Monch, L. Peter, and V. Sturm, Spectrochim. Acta B, 2001, 56: 637.
  • 4M. Hemmerlin, R. Meilland, H. Falk, P. Wintjens, and L. Paulard, Spectrochim. Acta B, 2001, 56: 661.
  • 5H. Bette, R. Noll, G. Muller, H. W. Jansen, Q. Nazikkol, and H. Mittelstadt, J. Laser Appl., 2005,17(3): 183.
  • 6H. M. Kuss, H. Mittelstaedt, and G. Mueller, J. Anal. At. Spectrom., 2005, 20(8): 730.
  • 7R. Sattmann, V. Sturm, and R. Noll, J. Phys. D, 1995, 28(10): 2181.
  • 8F. Colao, V. Lazic, R. Fantoni, and S. Pershin, Spectrochim. Acta B, 2002, 57: 1167.
  • 9A. Ciucci, M. Corsi, V. Palleschi, S. Rastelli, A. Salvetti, and E. Tognoni, Appl. Spectrosc., 1999, 53(8): 960.
  • 10E. Tognoni, G. Cristoforetti, S. Legnaioli, and V. Palleschi, Spectrochim. Acta B, 2010, 65: 1.