期刊文献+

智能电能表通信性能仿真平台隔离电源设计 被引量:1

Isolating Power Source Design of Communication Simulation Platform for Smart Electrical Meter
原文传递
导出
摘要 为更好地评估低压智能电能表的各项通信性能、建立专门的智能电能表通信性能仿真平台及克服低压电力线通信过程中高阻抗、高噪声、高污染的影响,研发了性能良好的干扰屏蔽措施,根据传导噪声的传导和耦合机理,提出一种传导噪声隔离供电电源设计方案。试验证明,该方案低压电力线窄带载波通信频段内的传导噪声隔离效果优于80dB,保持有效信号正常通信。 To calibrate the communication performance of low-voltage smart electrical meter, a specified communica- tion simulation platform need to be built, which can eliminate the effect of high resistance and high noise. Some novel in- terference shield approaches are introduced in this paper. More significantly, a conducted noise isolating power source for low power line communication is proposed based on conducted noise coupling principle. Test show that noise isolating per- formance of this proposal is better than 80dB, which keeps the normal communication qualification.
出处 《水电能源科学》 北大核心 2012年第12期178-180,共3页 Water Resources and Power
关键词 智能电能表 通信性能 仿真平台 隔离电源 耦合 smart electrical meter communication performance simulation platform isolating power source cou-pling
  • 相关文献

参考文献6

  • 1Zhai M Y. Measurements and Channel Characteristics of LV Power Line Communications Networks in China [A]. IEEE International Symposium on Power Line Communications and Its Applications [C]. Florida, USA, 2006 : 212-216.
  • 2Tsuzuki S, Takamatsu T, Nishio H,et al. An Esti- mation Method of the Transfer Function of Indoor Power-line Channels for Japanese Houses [A]. in Proc. IEEE International Symposium on Power- Lines Communications and Its Appiications [C]. Athens,Greece,2002 : 55-59.
  • 3So P L, Ma Y H. Development of a Test Bed for Power Line Communications [J]. IEEE Transac- tions on Consumer Electronics, 2004, 50:1 174- 1 182.
  • 4刘红,张东来,孙光伟.电力线载波中传输线模型的建立及应用[J].电力系统及其自动化学报,2002,14(3):27-31. 被引量:24
  • 5谢东垒,刘宗行,陈显圣.均匀传输线电路模型参数的测试[J].重庆大学学报(自然科学版),2006,29(5):24-27. 被引量:16
  • 6袁瑞铭,田海亭,宋伟,李丰,李顺昕,钟侃.低压载波通信信道阻抗测量与信号建模(英文)[J].中国电机工程学报,2012,32(4):161-168. 被引量:7

二级参考文献25

  • 1刘芳,刘思久,张礼勇.低压电力线载波通信的信道模型与模拟系统[J].哈尔滨理工大学学报,2006,11(4):67-70. 被引量:12
  • 2翟明岳,曾庆安.低压电力线通信信道的马尔柯夫特性研究[J].中国电机工程学报,2007,27(22):116-121. 被引量:25
  • 3Despina A, Theodore A. Measurements-based method for impedance characterization of residential loads[C]//IMTC 2004-Instrumentation and Measurement Technology Conference. Lake Como, Italy: IEEE, 2004: 375-379.
  • 4Lee W K, Fung G S K, Lam H Y, et al. Exploration on load signatures[C]//Intemational Conference on Electrical Engineering. Sapporo, Japan: IEEJ, 2004: 1-5.
  • 5Tsuzuki S, Takamatsu T, Yamada Y. An estimation method of the transfer function of indoor power line channels for Japanese houses[C]//Proc. 6th International Symposium on Power Line Communications and Its Applications. Athens, Greece: IEEE, 2002: 55-59.
  • 6Macfarlance I P. A probe for the measurement of electrical unbalance of networks and devices[J]. IEEE Trans. on Electromagnetic Compatibility, 1999, 41(1): 3-14.
  • 7Mingyue Z. Measurements and channel characteristics of LV power line communications networks in China[C]// IEEE International Symposium on Power Line Communications and Its Applications. Orlando, Florida, USA: IEEE, 2006: 212-216.
  • 8Nicholson J R, Malack J A. RF impedance of power lines and line impedance stabilization networks in conducted interference measurements[J]. IEEE Transactions on Electromagnetic Compatibility, 1973, 15(2): 84-86.
  • 9Malack J A, Engstrom J R. RF impedance of United States and European power lines[J]. IEEE Transactions on Electromagnetic Compatibility, 1976, 18(1): 36-38.
  • 10Vines R M, TrusseU H J, Shuey K C, et al. Impedance of the residential power-distribution circuit[J]. IEEE Transactions on Electromagnetic Compatibility, 1985, 27(1): 6-12.