摘要 神经介入治疗过程中,生物电极扮演着连接患者身体和医疗器械介面的角色。作为需要和患者身体直接接触的外源性部件,生物电极需要有很高的生物相容性,同时为了高效地传导人工电信号,生物电极的电学特性也需要得到保障。本文将系统地介绍生物电极的原理和结构,并结合实例进行说明。 Biomedical electrodes serve as the interlace between patients and medical devices, and pla)' important roles in the process of neural prosthesis. As a part of the medical device that is in direct contact with the body of patients, the materials of biomedical electrodes need high bio-compatibility, and in the mean time good electrical properties are also required in order for transmitting artificial electrical signals efficiently. In this paper, working mechanisms and design plans of biomedical electrodes will be reviewed, together with real examples from industry.
作者 张冠石
机构地区 本刊编辑部
出处 《中国医疗设备》 2012年第12期84-87,共4页 China Medical Devices
关键词 生物电极 神经介入治疗 双电层 生物相容性 biomedical electrodes neural prosthesis double-layer bio-compatibility
  • 相关文献

参考文献20

  • 1David C Grahame.The electrical double layer and the theory of electrocapillarity[J].Chem Rev,1947,41(3):441-501.
  • 2James A Davis,Robert O James,James O Leckie.Surface ionization and complexation at the oxide/water interface:I, computation of electrical double layer properties in simple electrolytes{J].J Colloid and Interface Science,1978,63(3):480-499.
  • 3Anthony M Dymond.Characteristics of the metal-tissue interface of stimulation electrodes[J].IEEE Transactions on Biomedical Engineering, 1976,23 (4) :274-280.
  • 4Peter Van Gerwen,Wim Laureyn,Wim Lanreys,et al.Nanoscaled interdigitated electrode arrays for biochemical sensors[J].Sensors and Actuators B:Chemical,1998,45(1-2):73-80.
  • 5Franks W,Schenker I,Schmutz,et al.Impedance characterization and modeling of electrodes for biomedical applications[J].IEEE Transactions on Biomedical Engineering,2005,52(7):1295-1302.
  • 6W Franks,F Heer, I McKay,et al.CMOS monolithic microdectrode army for stimulation and recording of natural neural networks[J]. Biosensors and Bioelectronics,2004,20(2):358-366.
  • 7E T McAdams,A Lackermeier, J A McLaughlin,et al.The linear and nonlinear electrical properties of the electrode electrolyte interface [l].Biosensors Bioelectron, 1995,10 (1-2):67-74.
  • 8A J Bard,L P,- Faulkner.Electrochemical methods[M].New York:Wiley,2001.
  • 9C Fonseca,A Martins da Silva.A novel dry active electrode for EEG recording[J].IEEE Transactions on Biomedical Engineering,2007,54(1):162-168.
  • 10W Portnoy,R David,L Akers.Biomedical electrode technology[M]. New York :Academic, 1974.