期刊文献+

Effectiveness of impedance monitoring during radiofrequency ablation for predicting popping 被引量:2

Effectiveness of impedance monitoring during radiofrequency ablation for predicting popping
暂未订购
导出
摘要 AIM: To retrospectively evaluate the effectiveness of impedance monitoring for predicting popping during radiofrequency ablation (RFA) using internally cooled electrodes. METHODS: We reviewed 140 patients (94 males, 46 females; age range 73.0 + 11.1 year) who underwent RFA between February 2006 and November 2008 with a modified protocol using a limited power delivery rather than a conventional one to avoid popping. All the patients provided their written informed consent, and the study was approved by the institutional review board. Intraprocedural impedances were measured for the study subjects, and the tumors were classified into three types according to the characteristics of their impedance curves: increasing, flat, or decreasing. The tumors were further sorted into seven subtypes (A-G) depending on the curvature of the impedance curve' s increase or decrease. Relative popping rates were determined for the three types and seven subtypes. A chi-square test was performed to estimate statistical significance.RESULTS: A total of 148 nodules treated by RFA were analyzed. The study samples included 132 nodules of hepatocellular carcinoma, 14 nodules of metastatic liver cancer, and two nodules of intrahepatic cholangio- carcinoma. The numbers of nodules with each imped- ance curve type were as follows: 37 increasing-type nodules, 43 fiat-type nodules, and 68 decreasing-type nodules. Popping occurrence rates were 24.3%, 46.5% and 64.7%, respectively. Flat-type nodules exhibited a significantly higher rate of popping compared to increasing-type nodules (P = 0.039). Decreasing-type nodules exhibited a significantly higher rate of popping compared to increasing-type nodules (P 〈 0.0001). No- tably, nodules that showed a sharp decrease in imped- ance in the latter ablation period (subtype E) exhibited a significantly higher rate of popping compared to other subtypes. CONCLUSION: Intraprocedural impedance monitoring can be a useful tool to predict the occurrence of pop- ping during liver tumor RFA performed with internally cooled electrodes. AIM:To retrospectively evaluate the effectiveness of impedance monitoring for predicting popping during radiofrequency ablation(RFA) using internally cooled electrodes.METHODS:We reviewed 140 patients(94 males,46 females;age range 73.0 ± 11.1 year) who underwent RFA between February 2006 and November 2008 with a modified protocol using a limited power delivery rather than a conventional one to avoid popping.All the patients provided their written informed consent,and the study was approved by the institutional review board.Intraprocedural impedances were measured for the study subjects,and the tumors were classified into three types according to the characteristics of their impedance curves:increasing,flat,or decreasing.The tumors were further sorted into seven subtypes(A-G) depending on the curvature of the impedance curve' s increase or decrease.Relative popping rates were determined for the three types and seven subtypes.A chi-square test was performed to estimate statistical significance.RESULTS:A total of 148 nodules treated by RFA were analyzed.The study samples included 132 nodules of hepatocellular carcinoma,14 nodules of metastatic liver cancer,and two nodules of intrahepatic cholangiocarcinoma.The numbers of nodules with each impedance curve type were as follows:37 increasing-type nodules,43 flat-type nodules,and 68 decreasing-type nodules.Popping occurrence rates were 24.3%,46.5% and 64.7%,respectively.Flat-type nodules exhibited a significantly higher rate of popping compared to increasing-type nodules(P = 0.039).Decreasing-type nodules exhibited a significantly higher rate of popping compared to increasing-type nodules(P < 0.0001).Notably,nodules that showed a sharp decrease in impedance in the latter ablation period(subtype E) exhibited a significantly higher rate of popping compared to other subtypes.CONCLUSION:Intraprocedural impedance monitoring can be a useful tool to predict the occurrence of popping during liver tumor RFA performed with internally cooled electrodes.
机构地区 Department of Surgery
出处 《World Journal of Gastroenterology》 SCIE CAS CSCD 2012年第41期5870-5878,共9页 世界胃肠病学杂志(英文版)
关键词 Radiofrequency ablation Internally cooledelectrode Popping LIVER COMPLICATION 阻抗曲线 射频消融 监测 预测 治疗 内部冷却 RFA 增长型
  • 相关文献

参考文献3

二级参考文献5

共引文献70

同被引文献5

引证文献2

二级引证文献9

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部