摘要 通过对大亚湾、岭澳核电站换热器失效案例进行调研,分析了引起核电站换热器腐蚀失效的原因,并进行机理分析,最后对核电站换热器的防腐蚀管理及维修策略管理提出建议。 By researching corrosion failure cases of heat exchangers in nuclear power plant, the corrosion failure of heat exchangers were analyzed. The corrosion causes and mechanisms of the heat exchangers were analyzed. It also provided some suggestions on anti-corrosion and maintenance management.
出处 《全面腐蚀控制》 2012年第11期63-66,共4页 Total Corrosion Control
关键词 核电站换热器腐蚀 nuclear power plant heat exchanger corrosion
  • 相关文献

参考文献3

  • 1A.J.Grunsky. Feedwater heater maintenance guide[M]. Palo Alto: EPRI, 2002, 1003470.
  • 2J.A.Beavers, A.K.Agrawal, W.E.Berry. Corrosion-related failures in feedwater heater [M]. Palo Alto: EPRI, 1983, CS-3184.
  • 3A.R.Jacobstein, J.A.Quinn, F.L.Wadsworth, R.S.WeUens. Failure cause analysis-feedwater heater[M]. Palo Alto: EPRI, 1981, CS-1776.