期刊文献+

高效液相色谱-串联质谱法测定人尿液中28种毒品的残留量 被引量:4

HPLC-MS/MS Determination of Residual Amounts of 28 Abused Drugs in Human Urine
在线阅读 下载PDF
导出
摘要 提出了高效液相色谱-串联质谱法测定人尿液中鸦片类、苯丙胺类和可卡因类等28种毒品含量的方法。试样用乙酸乙酯提取,离心分离,提取液于40℃氮气吹干后,用甲醇-水(30+70)溶液1mL溶解定容,用高效液相色谱-串联质谱检测。28种毒品的质量分数均在2.0~200μg·kg-1范围内呈线性关系,方法的检出限(3S/N)在1.0~2.0μg·kg-1之间。在空白尿液样品中加入5,10,50μg·kg-1混合标准溶液,测得28种毒品的回收率在61.0%~117%之间,相对标准偏差(n=6)在3.0%~14%之间。 A method of HPLC-MS/MS for the determination of 28 abused drugs, such as opioids, amphetamines and cocaines, in human urine was proposed. The sample was extracted with ethyl acetate, after centrifugation, the supernatant was taken and evaporated to dryness by N2-blowing at 40℃. The residue was taken up with 1.0 mL of a mixture of methanol and water (30+70) and analyzed by HPLC-MS/MS. Linear relationships between values of peak area and mass fraction of 28 abused drugs were kept in the same range of 2. 0-200 μg · kg 1, with detection limits (3S/N) in the range of 1.0-2.0μg · kg L. Recovery and precision of the method were tested by addition of mixed abused drugs standards at 3 concentration levels of 5,10,50μg · kg 1, giving values of recovery in the range of 61.0%-117% with RSD's (n=6) in the range of 3. 0%-14%
出处 《理化检验(化学分册)》 CAS CSCD 北大核心 2012年第11期1310-1314,共5页 Physical Testing and Chemical Analysis(Part B:Chemical Analysis)
基金 江苏出入境检验检疫局科技项目(2008KJ28)
关键词 高效液相色谱-串联质谱法 毒品 人尿液 HPLC-MS/MS Abused drugs Human urine
  • 相关文献

参考文献5

二级参考文献33

共引文献50

同被引文献83

  • 1陈令新,罗国安,王俭,刘科辉,王义明.毒品分析研究进展[J].药物分析杂志,2005,25(7):881-888. 被引量:14
  • 2金永春,蔡明招,黄晓兰,吴惠勤,朱志鑫.人血中10种常见毒品的GC-MS同时检测方法研究[J].分析测试学报,2007,26(2):151-155. 被引量:22
  • 3党王娟,何建平,周建华,计亚军,刘晓磊,梅天庆,力虎林.介孔碳负载铂催化剂的分散性和电催化活性[J].物理化学学报,2007,23(7):1085-1089. 被引量:12
  • 4张祥民.现代色谱分析[M].上海:复旦大学出版社,2006:150-152.
  • 5邓延倬 何金兰.高效毛细管电泳[M].北京:科学出版社,2000.100-115.
  • 6Papayannopoulos I A. The Interpretationof Collision-Induced Dissociation Tandem Mass-Spectraof Peptides. Mass Spectrometry Reviews, 1995, 14 (1): 49-73.
  • 7Biemann K. Sequening of Peptides by Tandem Mass- Spectrometryand High-Energy Collision-Induced Dissociation. Methods in Enzymology, 1990, 193: 455-479.
  • 8Syka J E P, Coon J J, Schroeder M J, et al. Peptide and protein sequence analysis by electron transfer dissociation mass spectrometry. Proceedings of the National Academy of Sciences of the United States of America, 2004, 101 (26): 9528-9533.
  • 9Zubarev R A, Kelleher N L, McLafferty F W. Electron capture dissociation of multiply charged protein cations. A nonergodic process. Journal of the American Chemical Society, 1998, 120 (13): 3265-3266.
  • 10Olsen J V, de Godoy L M F, Li G Q, et al. Parts per million mass accuracy on an orbitrap mass spectrometer via lock mass injection into a C-trap. Molecular & Cellular Proteomics, 2005, 4 (12): 2010- 2021.

引证文献4

二级引证文献15

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部