基于斯托克斯椭偏测量系统的多点定标法 被引量:17

Multi-Point Calibration Method Based on Stokes Ellipsometry System
原文传递
导出
摘要 斯托克斯椭偏仪可快速测量光束的偏振态,仪器矩阵的精确测量是斯托克斯椭偏仪一项非常重要的技术。为提高仪器矩阵的测量精度,基于四点定标法,提出了斯托克斯椭偏测量系统的多点定标法,并从理论上证明了该方法。在多点定标法的基础上采用六点定标法进行实验验证,结果表明采用多点定标法对系统定标是完全可行的,为斯托克斯椭偏仪的定标提供了新思路。同时六点定标法比四点定标法以及E-P定标法所获得的仪器矩阵更准确,在测量精度方面,该方法获得的斯托克斯参数的总均方根(RMS)偏差为3.15%。 Stokes ellipsometer can quickly measure polarization state of light beam. Accurate measurement of instrument matrix is one of the most important technology in stokes ellipsometer. In order to improve measurement accuracy of the instrument matrix, a method of multi-point calibration for stokes ellipsometry system is proposed and is proved in theory. Six-point calibration method based on multi-point calibration method is used on the system, which is verified by experiment. Results show that using multi-point calibration method calibration of the system is entirely feasible. It provides a new approach for calibration of Stokes ellipsometer, and six-point calibration method is more accurate than standard of four-point and E-P calibration method in acquiring matrix of the instrument. In measurement accuracy, the total root-mean-square (RMS) deviation of Stokes parameters is 3.15 %.
出处 《中国激光》 EI CAS CSCD 北大核心 2012年第11期163-167,共5页 Chinese Journal of Lasers
基金 国家自然科学基金(11172181)资助课题
关键词 光电子学 系统定标 分振幅 斯托克斯参量 optoelectronics calibration of system division-of-amplitude Stokes parameters
  • 相关文献

参考文献12

  • 1R. M. A. Azzam. Division-of-amplitude photopolarimeter (DOAP) for the simultaneous measurement of all four Stokes parameters of light[J]. Opt. Acta, 1982, 29(5): 685-689.
  • 2R. M. A. Azzam. Arrangement of four photo-detectors for measuring the state of polarization of light [J]. Opt. Lett., 1985, 10(7): 309-311.
  • 3R. M. A. Azzam, E. Masetti, I. M. Elminyawi el al.. Construction, calibration, and testing of a four-detector photopolarimeter[J]. Rev. Sci. Instrum., 1988, 59(1): 84-88.
  • 4D. Han, Y. S. Kin, Marilyn E. Norz. Stokes parameters as a Minkowskian four-vector[J]. Phys. Rev. E, 1997, 56 (5) 6065-6076.
  • 5R. M. A. Azzam, A. G. Lopez. Accurate calibration of the four-detector photopolarimeter with imperfect polarizing optical elements[J]. Opt. Soc. Am. A, 1989, 6(10):1513-1521.
  • 6S. Krishnan. Calibration, properties, and applications of the division of amplitude photopolarimeter at 632.8 nm and 1523 nm [J]. J. Opt. Soc. Am. A, 1992, 9(9): 1615-1622.
  • 7杜西亮,戴景民.光栅分振幅光偏振测量系统的研制[J].光电工程,2006,33(7):57-62. 被引量:16
  • 8杜西亮,戴景民.基于神经网络的分振幅光偏振仪的数据处理[J].中国激光,2007,34(1):89-93. 被引量:5
  • 9程敏熙,何振江,黄佐华.分振幅法偏振光斯托克斯参量测量系统[J].光电工程,2008,35(5):93-97. 被引量:25
  • 10王立波,石志东,殷俊,陈华.基于虚拟仪器的斯托克斯参量测试系统[J].激光与光电子学进展,2010,47(4):30-34. 被引量:7

二级参考文献63

共引文献66

同被引文献151

引证文献17

二级引证文献87

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部