摘要
在对数座火电厂贮灰场进行二维渗流有限元计算分析基础上 ,总结出影响贮灰场渗流分布的主要因素 ,提出可供工程借鉴的建议 。
Based on several two dimensional seepage finite element calculations in ash field of thermal power plant,the main factors of seelage field have been summarised.And some advises available to project were given.Finally,the result of two dimensional seepage finite element calculation was compared to the recorded saturation line.
出处
《四川大学学报(工程科学版)》
EI
CAS
CSCD
2000年第2期1-3,共3页