期刊文献+

CIAE强流ECR离子源研制 被引量:3

Development of High Current ECR Ion Source at CIAE
在线阅读 下载PDF
导出
摘要 本文介绍了研制的一台强流ECR微波离子源,其能从7mm直径的圆孔引出大于150mA的氢离子束(75keV),质子比达90%。该离子源采用独特的结构提高了离子源寿命。离子源在75keV、110mA束流条件下连续工作超过220h,束流中断2次,不间断工作时间超过150h。 A high current ECR ion source was introduced.The total hydrogen beam more than 150 mA at 75 keV can be routinely extracted from a single 7 mm diameter aperture with the proton fraction up to 90%.A unique structure to improve the reliability was adopted.The ion source was operated continuously for more than 220 h at 75 keV and 110 mA extracted hydrogen current,while two beam trips were recorded in the period,and uninterrupted operation time was about 150 h.
出处 《原子能科学技术》 EI CAS CSCD 北大核心 2012年第B09期544-546,共3页 Atomic Energy Science and Technology
基金 国家重点基础研究发展计划资助项目(2007CB209904)
关键词 ECR离子源 强流离子束 可靠性 ECR ion source high current beam reliability
  • 相关文献

参考文献2

  • 1WILLS J S C, LEWIS R A, DISERENS J, et al. A compact high current microwave driven ion source[J]. Rev Sci Instrum, 1998, 69 (1) : 65- 68.
  • 2SHERMAN J, ARVIN A, HANSBOROUGH L, et al. Status report on DC 130 mA, 75 keV proton inieetor[J]. Rev Sei Instrum, 1998, 69 (2): 1 003-1 008.