底面受火预应力混凝土空心板耐火极限由空心板跨中挠度、跨中挠度变化率和试件断裂破坏综合确定。通过5块预应力混凝土空心板底面受火耐火极限的对比试验,研究了不同持荷水平底面受火空心板的耐火极限。研究结果表明,分别持荷25%和50%极限荷载的空心板BP25和BP50的耐火极限分别为47 min和30 min,即随着持荷水平增加,底面受火空心板耐火极限明显降低。
The fire endurance of prestressed concrete hollow-core slab is determined not only by the mid-span displacement and the changing rate of mid-span displacement, but also by the failure of the slab. In order to learn the effect of the load level on the fire endurance, 5 specimens were experimentally studied. The fire endurances of BP25 ( the invariable load is 25% of ultimate load)and BP50(the invariable load is 50% of ultimate load)were 47min and 30min respectively. It was found that the fire endurance of prestressed concrete hollow-core slabs exposed to fire had an obvious decrease when the load level increased.