Effect of green tea particle size on near infrared spectrogram and nitrogen content model
原文传递
导出
摘要 近红外光谱分析对样品粒径大小和均匀度要求较高。试验采用2种粉碎机以及不同种类的绿茶,研究粒度对NIRS光谱图和模型的影响。结果表明样品粒度与近红外吸收强度相关,随着粒径的增大而增加;茶样粒径越小、越均匀,图谱稳定性越好。超离心研磨机适用于不同品种的绿茶,茶叶粉碎样完整且均匀度好,0.5mm的绿茶含氮量近红外分析模型外部验证RMSEP和相关系数分别为0.115、0.9935,模型的预测性能非常好,能满足检测要求。 Near infrared reflectance spectroscopy (NIRS) analysis has a higher request on sample size and evenness. With two kinds of grinder and green tea, the effect of green tea particle size on near infrared spectrogram and model were researched. The results show that sample particle size was related to near infrared absorbance which can increase following the increase of particle size. The particle size smaller and evenness can helpful for improving the spectrogram stability. The ultra-centrifugal grinding machine is suitable for different kinds of green tea, tea crushing sample is complete and the homogeneous degree is good. Near-infrared analysis model RMSEP and correlation coefficient of 0.5 mm of green tea nitrogen content is 0.115 and 0.9935 respectively. The prediction performance is very good and can meet the detection requirements.
出处 《食品科技》 CAS 北大核心 2012年第11期278-281,共4页 Food Science and Technology
基金 现代农业产业技术体系建设专项基金项目(nycytx-26)
关键词 近红外光谱技术 茶叶 粒度 含氮量 near infrared spectroscopy tea particle size nitrogen content
  • 相关文献

参考文献6

二级参考文献9

  • 1[1]American Association of Cereal Chemistry, Approved Methods of the American Association of Cereal Chemcal[M]. Ninth Edition, The Association: St Paul, MN,USA,1995.
  • 2[2]Stephen R D, Ronald E P,Karl H N, Sensitivity of Near-Infrared Absorption to Moisture Contents Versus Water Activity in Starch and Cellulose[J]. Cereal Chemistry,69(1):107~109.
  • 3李大群,分析化学,1989年,4卷,45页
  • 4邓勃,数理统计方法在分析测试中的应用,1984年,289,294页
  • 5Garrigues J M,Garrigues,Perez-Ponce,Garrigues S,et al.Fourier-transform infrared determination of nicotine in tobacco samples by transmittance measurements after leaching with CHCl3[].Analytica Chimica Acta.1998
  • 6Di Luzio C,Cardinale E,Cardinale E.Rapid near infrared reflectance analysis (NIRA) of mainstream smoke collected on Cambridge filter pads[].Beitrage Zur Tabakforschung International.1995
  • 7Aucott L S,Garthwaite P H.Transformations to reduce the effect of particle size in near-infrared spectra[].The Analyst.1988
  • 8石师林,严衍禄.付里叶变换近红外漫反射光谱分析仪器参数的确定[J].北京农业大学学报,1990(A06):67-71. 被引量:3
  • 9严衍禄,赵龙莲,李军会,张录达,闵顺耕.现代近红外光谱分析的信息处理技术[J].光谱学与光谱分析,2000,20(6):777-780. 被引量:115

共引文献122

同被引文献80

引证文献5

二级引证文献41

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部