期刊文献+

Fractionation of residual Al in natural water treatment from reservoir with poly-aluminum-silicate-chloride (PASiC): Effect of OH/Al, Si/Al molar ratios and initial pH 被引量:7

Fractionation of residual Al in natural water treatment from reservoir with poly-aluminum-silicate-chloride (PASiC): Effect of OH/Al, Si/Al molar ratios and initial pH
原文传递
导出
摘要 An aluminum fractionation study was conducted for a surface reservoir water treatment to understand the performance of poly- aluminum-silicate-chloride (PASiC) in terms of the residual A1 fractions as a function of initial pH. The coagulation performance expressed as turbidity and organic matter removal was established as supporting data. Some extra data were evaluated in terms of the residual A1 ratio of the composite PASiC coagulant. The main residual A1 sources were the A1 fractions derived from the use of PASiC. The turbidity and organic matter removal ability was optimal at initial pH 6.00-7.00, while the concentrations of various residual A1 species and the residual A1 ratio of PASiC were minimal at an initial pH range of 7.00-8.00. Under the conditions of OH/AI molar ratio = 2.00 and Si/A1 molar ratio = 0.05, PASiC had superior coagulation performance and comparatively low residual A1 concentrations. The A1 fraction in the composite PASiC coagulant seldom remained under such conditions. Experimental data also indicated that the suspended (filterable) AI fraction was the dominant species, and organic-bound or organo-A1 complex A1 was considered to be the major species of dissolved A1 in water treated by PASiC coagulation. Additionally, the dissolved inorganic monomeric A1 species dominated the dissolved monomeric A1 fraction. An aluminum fractionation study was conducted for a surface reservoir water treatment to understand the performance of poly- aluminum-silicate-chloride (PASiC) in terms of the residual A1 fractions as a function of initial pH. The coagulation performance expressed as turbidity and organic matter removal was established as supporting data. Some extra data were evaluated in terms of the residual A1 ratio of the composite PASiC coagulant. The main residual A1 sources were the A1 fractions derived from the use of PASiC. The turbidity and organic matter removal ability was optimal at initial pH 6.00-7.00, while the concentrations of various residual A1 species and the residual A1 ratio of PASiC were minimal at an initial pH range of 7.00-8.00. Under the conditions of OH/AI molar ratio = 2.00 and Si/A1 molar ratio = 0.05, PASiC had superior coagulation performance and comparatively low residual A1 concentrations. The A1 fraction in the composite PASiC coagulant seldom remained under such conditions. Experimental data also indicated that the suspended (filterable) AI fraction was the dominant species, and organic-bound or organo-A1 complex A1 was considered to be the major species of dissolved A1 in water treated by PASiC coagulation. Additionally, the dissolved inorganic monomeric A1 species dominated the dissolved monomeric A1 fraction.
出处 《Journal of Environmental Sciences》 SCIE EI CAS CSCD 2012年第11期1908-1916,共9页 环境科学学报(英文版)
基金 supported by the Scientific Technology Research and Development Program of Shandong,China (No.2010GZX20605) the Chinese National Foundation of Natural Sciences (No.21077066) the Natural Science Foundation of Shandong Province, China (No.ZR2010BM014) the Graduate Innovation Foundationof Shandong University (No.yyx10010, GIFSDU) the Shanghai Tongji Gao Tingyao Environmental Science &Technology Development Foundation (STGEF) the Scholarship Award for Excellent Doctoral Student granted by Ministry of Education
关键词 coagulation performance OH/A1 and Si/AI molar ratio poly-aluminum-silicate-chloride (PAniC) resi0ual AI speclataon residual A1 ratio coagulation performance OH/A1 and Si/AI molar ratio poly-aluminum-silicate-chloride (PAniC) resi0ual AI speclataon residual A1 ratio
  • 相关文献

参考文献28

  • 1Berthon G, 2002. Aluminium speciation in relation to alumini- urn bioavailability, metabolism and toxicity. Coordination Chemistry Reviews, 228(2): 319-341.
  • 2Flaten T P, 2002. Aluminium in tea-concentrations, specia- tion and bioavailability. Coordination Chemistry Reviews, 228(2): 385-395.
  • 3Gao B Y, Hahn H H, Hoffmann E, 2002. Evaluation of aluminum-silicate polymer composite as a coagulant for water treatment. Water Research, 36(14): 3573-3581.
  • 4Gao B Y, Yue Q Y, Wang B J, Chu Y B, 2003. Poly- aluminum-silicate-chloride (PASiC)-a new type of compos- ite inorganic polymer coagulant. Colloids and Surfaces A: Physicochemical and Engineering Aspects, 229(1-3): 121- 127.
  • 5Gao B Y, Yue Q Y, Wang Y, 2007. Coagulation performance of polyaluminum silicate chloride (PASiC) for water and wastewater treatment. Separation and Purification Technol- ogy, 56(2): 225-230.
  • 6Gjessing E T, 1976. Physical and Chemical Characteristics of Aquatic Humus. Ann Arbor Science, Ann Arbor Mich, 46- 48.
  • 7Guibaud G, Gauthier C, 2003. Study of aluminium concentration and speciation of surface water in four catchments in the Limousin region (France). Journal of Inorganic Biochem- istry, 97(1): 16-25.
  • 8Guibaud G, Gauthier C, 2005. Aluminium speciation in the Vienne River on its upstream catchment (Limousin region, France). Journal of Inorganic Biochemistry, 99(9): 1817- 1821.
  • 9Istv'an L, 1993. On the type of bond developing between the aluminium and iron(HI) hydroxide and organic substances. Water Science and Technology, 27(11): 242-252.
  • 10Kim S H, Moon B H, Lee H I, 2001. Effects of pH and dosage on pollutant removal and floc structure during coagulation. Microchemistry Journal, 68(2-3): 197-203.

同被引文献123