期刊文献+

Study on Pre-treatment of the Domestic Sewage by Water-dropping Aeration Zeolite Bed Technology

Study on Pre-treatment of the Domestic Sewage by Water-dropping Aeration Zeolite Bed Technology
在线阅读 下载PDF
导出
摘要 [ Objective] The research aimed to study pre-treatment effect of the domestic sewage by water-dropping aeration zeolite bed technology. [ Method] By water-dropping aeration manner, we conducted sewage reoxygenation. Zeolite was used to replace traditional contact oxidization fill- er. We inspected oxygenation effect of the water-dropping aeration manner and removal efficiency of the pollutant in sewage after biological contact oxidation. [ Result] Under the experimental condition with water-dropping heights of 0.30, 0.45 and 0.60 m, average added values of the dissolved oxygen for raw water were respectively 2.4, 3.6 and 4.2 rag/l_ after water-dropping aeration. Under the situation with average HRT of 2 h, when COD, TN and TP of the influent were respectively 309.0 -464.0, 33.3 -95.0 and 4.0 -7.5 mg/L, their corresponding average removal rates were 47.25%, 46.39% and 40.75%. [ Conclusion] The research conducted useful attempt for high-efficiency and low-cost treatment of the domestic sewaqe in rural area. [ Objective] The research aimed to study pre-treatment effect of the domestic sewage by water-dropping aeration zeolite bed technology. [ Method] By water-dropping aeration manner, we conducted sewage reoxygenation. Zeolite was used to replace traditional contact oxidization fill- er. We inspected oxygenation effect of the water-dropping aeration manner and removal efficiency of the pollutant in sewage after biological contact oxidation. [ Result] Under the experimental condition with water-dropping heights of 0.30, 0.45 and 0.60 m, average added values of the dissolved oxygen for raw water were respectively 2.4, 3.6 and 4.2 rag/l_ after water-dropping aeration. Under the situation with average HRT of 2 h, when COD, TN and TP of the influent were respectively 309.0 -464.0, 33.3 -95.0 and 4.0 -7.5 mg/L, their corresponding average removal rates were 47.25%, 46.39% and 40.75%. [ Conclusion] The research conducted useful attempt for high-efficiency and low-cost treatment of the domestic sewaqe in rural area.
作者 GAO Chang-fei
出处 《Meteorological and Environmental Research》 2012年第10期48-51,共4页 气象与环境研究(英文版)
基金 Supported by Science and Technology Key Special Item of the National Water Body Pollution Control and Treatment, China(2010BAC68B02)
关键词 Water-dropping aeration Zeolite bed Domestic sewage China Water-dropping aeration Zeolite bed Domestic sewage China
  • 相关文献

参考文献5

二级参考文献23

共引文献48

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部