摘要
由于游泳馆功能的特殊性与复杂性,在空调系统设计中往往存在很多难点。沧州游泳馆在空调系统的设计过程中,针对室内设计参数、气流组织、防结露、湿度控制、池区采暖等问题进行了详细分析,并最终提出了解决方案。
Because of the functional specificity and complexity for natatorium,there are usually many difficulties in designing the airconditioning systems.In the HVAC design of Cangzhou Natatorium,the interior design parameters,airflow organization,dewing-proof,humidi ty control and pool heating were analyzed with solutions.
出处
《建筑节能》
CAS
2012年第10期10-12,49,共4页
BUILDING ENERGY EFFICIENCY
关键词
除湿热泵
气流组织
防结露
坐椅送风
dehumidification heat pump system
airflow organization
dewing-proof
chair ventilation