期刊文献+

支架辅助机械解脱弹簧圈栓塞治疗颅内宽颈动脉瘤的临床应用 被引量:1

CLINICAL APPLICATION IF STENT-ASSISTED MECHANICALLY-DETECHABLE COIL EMBOLIXATION IN TREATING INTRACRANIAL WILD-NECKED ANEURYSMS
暂未订购
导出
摘要 目的:探讨支架辅助机械解脱弹簧圈栓塞治疗颅内宽颈动脉瘤中的安全性、疗效、技术优势及临床应用价值。方法:采用Seldinger穿刺技术,应用颅内支架辅助瘤颈成形术结合AxiumTM弹簧圈栓塞治疗颅内宽颈动脉瘤26例。结果:所有动脉瘤均成功植入支架,其中Boston公司的Neuroform支架19枚、Cordis公司的Enterprise支架7枚。术后即可完全填塞20例,大部分填塞6例,载瘤动脉通畅。术后随访6~12个月,未发现出血或脑血栓形成。结论:联合使用支架辅助机械弹簧圈栓塞是治疗颅内宽颈动脉瘤安全有效的方法,支架后释放技术显著提高动脉瘤颈覆盖率而达到血管重建目的,使宽颈动脉瘤的介入治疗成为可能,使颅内动脉瘤介入治疗技术成功率、安全性和疗效得到进一步提高。 Objective:To discuss the safety,efficacy and advantages,the clinical application of stent-assisted mechanically-detechable coil embolization in treating intracranial wild-necked aneurysms.Method:Twenty-six patients with wild-necked aneurysms were treated with embolization therapy by stent-assisted technique combined with the use of mechanically-detechable AxiumTMcoil through Seldinger technique.Results:Stent placement successed Technically in all of the wild-necked aneurysms,including 19 Boston Neuroform stent,7Cordis Enterprise stent.Total occlusion was achieved immediately in 20 cases and more than 90% in 6 cases,the patients recovered well with patency of the parent arteries.All the patients recovered well.Neither rebleeding nor thrombosis-related sympotoms occurred during a follow-up period of 6-12months.Conclusion:For the treatment of intracranial wild-necked aneurysms,stent-assisted mechanically-detechable coil embolization technique is safe and effective.Stenting after coiling techniques can facilitate the improvement of neck forvascular reconstruction,and technical successful rate,safety and efficacy.
出处 《牡丹江医学院学报》 2012年第5期22-25,共4页 Journal of Mudanjiang Medical University
关键词 颅内动脉瘤 支架 机械解脱弹簧圈 栓塞 介入治疗 Intracranial aneurysms Stent Mechanically-detechable coil embolization Intervention treatment
  • 相关文献

参考文献6

  • 1Hop JW, Rinkel GJ, Algra A, et al. Case- fatality rates and functional outcome after subarachnoid hemorrhage: systematic review [ J ]. Stroke. 1997,28:660 - 664.
  • 2刘建民,洪波,许奕,秦永文,赵文元,周晓平,黄清海.血管内支架及电解可脱卸弹簧圈治疗颅内椎动脉梭形动脉瘤[J].第二军医大学学报,2000,21(11):1052-1054. 被引量:59
  • 3Lubicz B, Leclerc X , Levivier M, et al. Retractable self - expandable stent for endovascular treatment of wild - necked intracranial aneu- rysms : preliminary experience [ J ]. Neurosurgery, 2006,589 ( 3 ) : 451 - 457.
  • 4张鑫,刘建民,周晓平,许奕,洪波,黄清海,张珑,佘家贵,赵瑞.血管内支架结合弹簧圈栓塞犬宽颈动脉瘤的病理学研究[J].中华神经外科杂志,2007,23(8):585-588. 被引量:28
  • 5Wanke I-forsting M. Stenting for intracranial wide wild - necked an- eurysms more than mechanical protection Neuroradiology [ J ] , 2008, 50(12) :991 -998.
  • 6Lanzino G, Wakhloo AK, Fessler RD, et al. Efficacy and current limi- tation of intravaseular stents for intracranial internal carotid , verte- bral, and basilar artery aneurysms [ J ]. J Neurosurg, 1999,91 (4) :538 - 546.