期刊文献+

牙科镍铬合金烤瓷烧结后再抛光的耐腐蚀性能研究

Influence of Polishing on Corrosion Resistance of Fired Ni-Cr Alloy
暂未订购
导出
摘要 目的在模拟口腔环境下,观察烤瓷熔附镍铬合金基底面经烧结后再抛光的电化学腐蚀行为。方法采用恒电位测量极化曲线法,测定经烤瓷烧结再抛光镍铬合金在人工唾液中的自腐蚀电流密度(Icorr)、极化电阻(Rp)与自腐蚀电位(Ecorr),并与未抛光组(对照组)进行比较分析。结果实验组镍铬合金自腐蚀电流密度为0.958μAcm-2,低于对照组4.881μAcm-2(P<0.05);而实验组极化电阻与自腐蚀电位均显著高于对照组(P<0.05)。结论烤瓷熔附镍铬合金经烤瓷烧结后再抛光处理,能明显提高其耐腐蚀性能,降低腐蚀速率。 Objective To evaluate the corrosion behavior of fired Ni-Cr alloy after polishing in artificial saliva.Methods Electrochemical methods were used to measure the self-corrosion current density(Icorr),polarization resistance(Rp) and self-corrosion potential(Ecorr) of two subjects.And the polarization curves of them were recorded at the same time.Results The Icorr of polished Ni-Cr alloy(0.958μAcm-2) was lower than that of control group(4.881μAcm-2).However,the Rp(69.10 kΩcm2) and Ecorr(-276.19mv) of polished Ni-Cr alloy was higher than that were not polished(25.05 kΩcm2,-313.25 mv),(P0.05).Conclusion The corrosion resistance of fired Ni-Cr alloy after polishing was better than that were not,while the speed of corrosion was lower.
作者 朱政
出处 《中国医药指南》 2012年第29期5-6,共2页 Guide of China Medicine
基金 江苏高校优势学科建设工程资助项目(项目编号:2011-137)
关键词 镍铬合金 腐蚀 极化曲线 人工唾液 Ni-CrAlloy Corrosion Polarization curve Artificial saliva
  • 相关文献

参考文献7

二级参考文献25

  • 1刘恒全,张勇,强华,郝静,朱生发,黄楠.医用钛合金在体内的抗蚀性能及其影响因素[J].腐蚀与防护,2007,28(11):595-597. 被引量:5
  • 2朱国威,杨晓红,陈丽娅,陈林.非贵金属烤瓷冠修复后牙龈组织和血液中镍铬元素含量分析[J].华西口腔医学杂志,2004,22(4):284-286. 被引量:71
  • 3贾燕.钛合金属烤瓷冠修复的临床评价[J].口腔材料器械杂志,2005,14(1):54-55. 被引量:2
  • 4石培荔,滕伟,周雅彬,张新春,米乃元.含钛镍铬合金的腐蚀性能研究[J].口腔颌面修复学杂志,2006,7(3):213-216. 被引量:11
  • 5Wataha JC.Biocompatibility of dental casting alloys:A review[J].J Prosthet Dent,2000,83(2):223-234,
  • 6Roach MD,Wolan Jr,Parsell DE,et al.Use of X-ray photoelectron spectroscopy and cyclic polarization to evaluate the corrosion behavior of six nlckel-chromium alloys before and after porcelain-fused-to-metal firing[J].J Prosthet Dent,2000,84(6):623-634.
  • 7Kuphasuk C,Oshide Y,Andras CJ,et al.Electrochemical corrosion of titanium and titanium-based alloys[J].J Prosthct Dent,2001,85 (2):195-202.
  • 8Sun D,Monaghan P,Brantley WA,et al.Potentiodynamic polarization study of the in vitro corrosion behavior of 3 high-palladium alloys and a gold-palladium alloy in 5 media[J].J Prosthet Dent,2002,87(1):86-93.
  • 9O'Brien.Dental materials and their selection[M].3rd ed.Chicago:Quintessence Publishing Company Incorporated,2002:362-366.
  • 10Kuphasuk C,Oshide Y,Andres CJ,et al.Electrochemical corrosion of titanium and tltanium-based alloys[J].J Prosthet Dent,2001,85 (2):195-202.

共引文献15

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部