期刊文献+

CT导航下经皮骶髂螺钉固定技术治疗骨盆后环损伤的临床疗效评价 被引量:3

Evaluation of CT-guided Percutaneous Iliosacral Screw Fixation in Treating Unstable Pelvic Fracture
原文传递
导出
摘要 目的探讨CT导航下经皮骶髂螺钉固定技术治疗骨盆环损伤的安全性及临床疗效。方法对2009年1月-2011年3月期间我科收治的16例骨盆后环骨折脱位患者资料进行回顾性分析,所有患者均在计算机导航系统辅助下采用经皮骶髂螺钉固定技术进行治疗。结果 16例患者骶1平面共植入18枚骶髂螺钉,其中14例单侧植入1枚螺钉。14例患者获得随访,随访时间14~49个月,平均19个月。根据Majeed临床效果评定标准:满意8例,良好5例,差1例。所有随访患者均无神经、血管损伤、骶髂螺钉松动、断裂等并发症。结论经皮骶髂螺钉固定技术是恢复骨盆后环稳定性的一种安全、有效的方法,具有创伤小、临床效果好、并发症少、手术操作简便、性价比高等优势,值得临床推广。 Objective To investigate the safety and efficacy of CT-guided percutaneous iliosacral screw fixation for unstable pelvic fracture. Methods We retrospectively analyzed the clinical data of 16 patients with unstable pelvic ring fracture-dislocation admitted to our department from January 2009 to March 2011. All patients were treated by CT-guided percutaneous iliosacral screw fixation. Results A total of 18 iliosacral screws were implanted, with 14 cases of unilateral implantation of one screw. Fourteen patients were followed up for 14 to 49 months, with an average follow-up time of 19 months. According to Majeed evaluation criteria, the functional outcomes were excellent in 8 patients, good in 5, and poor in 1. No nerve or vascular injury, incision infection, loose screw or other complications were detected. Conclusion CT guided percutaneous iliosacral screw fixation is a safe and effective procedure for unstable pelvic fracture, with minimal invasion, good clinical outcome, few complications, and simple procedures.
出处 《华西医学》 CAS 2012年第10期1451-1453,共3页 West China Medical Journal
关键词 骶髂关节损伤 CT导航 骶髂螺钉 疗效 Sacroiliac joint injury CT navigation Iliosacral screw Therapeutic effect
  • 相关文献

参考文献11

  • 1Chong KH, Decoster T, Osier T, et al, Pelvic fractures and mortality[J]. Iowa Orthop J, 1997, 17:110-114.
  • 2Ebraheim NA, Rusin JJ, Coombs R J, et al. Percutaneous computed- tomography-stabilization of pelvic fractures: preliminary report[J]. J Orthop Trauma, 1987, 1(3): 197-204.
  • 3Blake-Toker AM, Hawkins L, Nadalo L, et al. CT guided percutaneous fixation of sacroiliac fractures in trauma patients[J]. J Trauma, 2001, 51(6): 1117-1121.
  • 4Ziran BH, Smith WR, Towers J, et al. Iliosacral screw fixation of the posterior pelvic ring using local anaesthesia and computerised tomography[J]. J Bone Joint Surg Br, 2003, 85(3): 411-418.
  • 5Zwingmann J, Konrad G, Kotter E, et al. Computer-navigated iliosacral screw insertion reduces malposition rate and radiation exposure[J]. Clin Orthop Relat Res, 2009, 467(7): 1833-1838.
  • 6Young JW, Burgess AR, Brumback RJ, et al. Pelvic fractures: value of plain radiography in early assessment and management[J]. Radiology, 1986, 160(2): 445-451.
  • 7Moed BR, Abroad BK, Craig JO, et al. Intraoperative monitoring with stimulus-evoked electromyography during placement of iliosacral screws. An initial clinical study[J]. J Bone Joint Surg Am, 1998, 80(4): 537-546.
  • 8van den Bosch EW. Van zwienen CM, van Vugt AB. Fluoroscopic positioning of sacroiliac screws in 88 patients[J]. J Trauma, 2002, 53(1): 44-48.
  • 9高伟强,王光林,刘华渝,吴刚,池雷霆,方跃,刘雷.经皮骶髂螺钉固定技术治疗不稳定骨盆骨折的疗效评价[J].中国修复重建外科杂志,2008,22(3):321-323. 被引量:38
  • 10洪华兴,洪正华,陈海啸,朱忠,林列.CT导引骶髂螺钉固定治疗垂直不稳定骨盆后环骨折[J].中华创伤杂志,2011,27(8):704-707. 被引量:7

二级参考文献24

  • 1谢增如,詹玉林.垂直不稳定骨盆骨折的治疗[J].中国修复重建外科杂志,2006,20(11):1156-1157. 被引量:9
  • 2张前法,庞清江,葛志斌,汤涛,陈良,袁欣华.骨盆后环损伤内固定重建方法的选择[J].中国修复重建外科杂志,2006,20(12):1214-1216. 被引量:14
  • 3Routt ML, Kregor PJ, Simonian PT, et al. Early results of percutaneous iliosacral screws placed with the patient in the su- pine position. J Orthop Trauma, 1995, 9 (3) :207 -214.
  • 4Routt MLJ, Simonian PT, Mills WJ. Ilio- sacral screw fixation: early complications of the percutaneous technique. J Orthop Trauma, 1997, 11(8):584-589.
  • 5Matta JM, Saucedo T. Internal fixation of pelvic ring fractures. Clin Orthop Relat Res, 1989, (242):83-97.
  • 6Majeed SA. Grading the outcome of pelvic fractures. J Bone Joint Surg ( Br), 1989,71(2):304 -306.
  • 7Ricci WM, Padberg AM, Borrelli J. The sig- nificance of anode location for stimulus - e- voked electromyography during iliosacral screw placement. J Orthop Trauma, 2003, 17(2) 05 -99.
  • 8Sagi HC, Lindvall EM. Inadvertent in- traforaminal iliosacral screw placement de- spite apparent appropriate positioning on intraoperative fluoroscopy. J Orthop Trau- ma, 2005, 19(2) :130 - 133.
  • 9Sciulli RL, Daffner RH, Altman DT, et al. CT- guided lliosacral screw place- ment: technique and clinical experience. Am J Roentgenol, 2007, 188 (2): W181 - W192.
  • 10Griffin DR, Starr AJ, Reinert CM, et al. Vertically unstable pelvic fractures fixed with percutaneous iliosacral screws: does posterior injury pattern predict fixation failure? J Orthop Trauma, 2003,17 (6) : 399 - 405.

共引文献43

同被引文献41

引证文献3

二级引证文献12

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部