期刊文献+

双源64排CT对冠脉狭窄程度评价能力的对比研究

Comparative study of dual-source 64 CT in evaluating coronary stenosis capability
暂未订购
导出
摘要 目的探讨双源64排CT对冠脉狭窄程度评价的准确性及应用价值。方法对比分析85例临床拟诊为冠心病患者的双源CT(DSCT)冠脉成像及经导管冠状动脉造影(CAG)资料,以CAG结果为金标准,评价DSCT诊断冠脉狭窄程度≥50%的准确性。结果 DSCT诊断冠心病的敏感度为63.6%、特异度为90.7%、阳性预测值为77.4%、阴性预测值为83.2%、准确度为81.6%。ROC曲线下面积为0.803,诊断准确度达到中等。结论 DSCT诊断冠脉狭窄≥50%的准确性受一定因素影响,能达到中等水平,是一种简便易行、安全有效的无创性检查方法。 Objective To explore the clinical value and positioning capability of dual-source 64 CT(DSCT) in coronary stenosis.Methods Comparing the dual-source 64-slice CT(DSCT) with coronary angiography(CAG) data which 85 patients would been diagnosis for coronary heart disease in the clinical.For CAG results as the gold standard,then evaluating the DSCT diagnostic coronary stenosis≥50% accuracy.Results DSCT sensitivity was 63.6%,specificity was 90.7%,positive predictive value was 77.4%,negative predictive value was 83.2% and the accuracy was 81.6%.The area under the ROC curve was 0.803,achieved middle-diagnostic accuracy.Conclusion DSCT is affected by certain factors in the diagnosis of coronary stenosis≥50%.It is a simple,safe and effective noninvasive method.
出处 《宁夏医学杂志》 CAS 2012年第10期965-966,共2页 Ningxia Medical Journal
关键词 冠心病 冠状动脉造影 双源CT Coronary heart disease Coronary angiography Dual-sourc CT
  • 相关文献

参考文献7

二级参考文献16

  • 1陈家荣,唐立钧.双源CT冠状动脉血管成像技术及临床应用[J].实用医技杂志,2008,15(13):1661-1663. 被引量:2
  • 2李佩玲,徐克,黎庶,王强.心率对16层螺旋CT冠状动脉造影图像质量的影响及其重建相位窗的优选[J].中国介入影像与治疗学,2006,3(1):18-22. 被引量:22
  • 3王继琛,邱建星,孙晓伟,高莉,刘建新,唐光健,蒋学祥.64层螺旋CT冠状动脉成像时心率对成像质量的影响[J].中国医学影像技术,2006,22(10):1481-1484. 被引量:46
  • 4Flohr TG,McCollough CH,Bruder H,et al.First Performance Evaluation of a Dual-source CT (DSCT)System[J].Eur Radiol,2006,16(2):256-268.
  • 5Scanlon PJ, Faxon DP, Audet AM, et al. ACC/AHA guidelines for coronary angiography : A report of the American College of Cardiology/American Heart Association Task Force on practice guidelines ( Committee on Coronary Angiography ) developed in collaboration with the Society for Cardiac Angiography and Interventions[J]. J Am Coil Cardiol, 1999, 33 (6) : 1756-1758.
  • 6Fine J J, Hopkins CB, Hall PAX, et al. Noninvasive coronary angiography : agreement of multi-slice spiral computed tomography and selective catheter angiography[J]. Internat J Cardiovascular Imaging, 2004, 20 ( 6 ) : 549-552.
  • 7Nieman K, Demartiri F, Lemos PA, et al. Reliable noninvasive coronary angiography with fast submillirneter muhislice spiral computed tomography[J]. Circulation, 2002, 106 ( 16 ) : 2051-2054.
  • 8Aehenbach S, Ropers D, Pohle FK, et al. Detection of coronary artery stenosis multi-detector CT with 16 × 0.75 collimation and 375ms rotation[J]. EurHeart, 2005, 26 (19) : 1978-1986.
  • 9Cury RC, Ferencik M, Achenbach S, et al. Accuracy of 16-slice multi- detector CT to quantify the degree of coronary artery stenosis : assessment of cross-sectional and longitudinal vessel re-constructions[J]. Eur J Radiology, 2006, 57 ( 3 ) : 345-350.
  • 10I,eschka S, Alkadhi H, Plass A, et al. Accuracy of MSCT Coronary Angiography with 64-slice Technology : First Experience[J]. Eur Heart, 2005, 26 : 1482-1487.

共引文献55

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部