摘要 石油化工可燃、易燃、易爆储罐区的火灾危险性、危害性大,消防要求高,此类罐区的消防设计主要有消防冷却水和泡沫消防两系统。论述了可燃液体储罐组消防冷却水和空气泡沫消防系统的组成及设计,着重对消防冷却水系统、空气泡沫系统的选择、系统控制及泡沫液管道的布置作了详细介绍。 The tank farm for combustible,inflammable,and explosive petrochemical media has great potential fire and harm hazard,so,the fire-fighting requirements are very stringent. The fire fighting designed for this type of tank farm mainly includes the fire-fighting cooling water system and foam fire-fighting system. The author discusses the composition and design of the fire-fighting cooling water system and the air foam fire-fighting system for the combustible-liquid storage tank group, and gives a detailed introduction to the selection of the fire-fighting cooling water system and the air foam system, the system control,and the configuration of foam liquid pipes.
作者 谢志富
机构地区 南化集团设计院
出处 《硫磷设计与粉体工程》 2000年第4期13-16,共4页 Sulphur Phosphorus & Bulk Materials Handling Related Engineering
关键词 可燃液体 储罐 消防给水 泡沫灭火 消防设计 combustible liquid,storage tank fire-fighting water supply,foam fire-fighting,design