期刊文献+

Late course shrinking gross tumor volume (GTV) and boost radiotherapy for a special left lung cancer patient whose right lung was resected: a case report

右肺全切患者左肺中心型肺癌后程缩野加量放疗后长期存活1例报道(英文)
在线阅读 下载PDF
导出
摘要 We reported a special case of a locally advanced squamous cell carcinoma of the left lung. Due to pulmonary tuberculosis, the patient had underwent a complete right-side pulmonary lobectomy 20 years ago. Left lung supports his life, he is unable to carry on an operation treatment, so he accepted radiotherapy. Firstly, we defined gross tumor volume (GTV1) by CT simulation location, three-dimensional conformal radiotherapy (3D-CRT) was used until tumor dose reached 50 Gy/25 f. Secondly, by repeating the planning CT scan, defined GTV2, continued to radiotherapy by 2.5 Gy/f until the dose was 65 Gy/31 f. Using the same method for third CT scan, defined GTV3, continued to radiotherapy by 3 Gy/f until the total dose was 74 Gy/34 f. After radiotherapy, the patient acquired complete response and he had no obvious side-effect of radiotherapy. There has been no recurrence for 5 years now.
机构地区 Department of Oncology
出处 《The Chinese-German Journal of Clinical Oncology》 CAS 2012年第11期665-667,共3页 中德临床肿瘤学杂志(英文版)
关键词 non-small cell lung cancer three-dimensional conformal radiotherapy (3D-CRT) boost radiotherapy shrinking gross tumor volume 肺癌 放疗 肿瘤 病例报告 患者 体积 CT扫描 放射治疗
  • 相关文献

参考文献7

  • 1Bradley J, Graham MV, Winter K, et al. Toxicity and outcome results of RTOG 9311: a phase l-ll dose-escalation study using three-di-mensional conformal radiotherapy in patients with inoperable nonsmall-cell lung carcinoma. Int J Radiat Oncol Biol Phys, 2005, 61: 318-328.
  • 2Erridge SC, Seppenwoolde Y, Muller SH, et al. Portal imaging to assess set-up errors, tumor motion and tumor shrinkage during conformal radiotherapy of non-small-cell lung cancer. Radiother Oncol, 2003, 66: 75-85.
  • 3Britton KR, Starkschall G, Tucker SL, et al. Assessment of gross tumor volume regression and motion changes during radiotherapy for non-small-cell lung cancer as measured by four-dimensional computed tomography. Int J Radiat Oncol Biol Phys, 2007,68:1036-1046.
  • 4Ramsey CR, Langen KM, Kupelian PA, et al. Atechnique for adaptive image-guided helical tomotherapy for lung cancer. Int J Radiat Oncol Biol Phys, 2006, 64:1237-1244.
  • 5Woodford C, Yartsev S, Dar AR, et al. Adaptive radiotherapy planning on decreasing gross tumor volumes as seen on megavoltage computed tomography images. Int J Radiat Oncol Biol Phys, 2007, 69:1316-1322.
  • 6Engelsman M, Remeijer P, van Herk M, et al. Field size reduction enables iso-NTCP escalation of tumor control probability for irradiation of lung tumors. Int J Radiat Oncol Biol Phys, 2001,51:1290-1298.
  • 7Feng M, Kong FM, Gross M, ef al. Using fluorodeoxyglucose positron emission tomography to assess tumor volume during radiotherapy for non-small-cell lung cancer and its potential impact on adaptive dose escalation and normal tissue sparing. Int J Radiat Oncol Biol Phys, 2009, 73:1228-1234.