关于建筑热质对太阳能空气采暖建筑热稳定性影响的研究 被引量:1

STUDY ON EFFECT OF THERMAL MASS ON THERMAL STABILITY OF BUILDING WITH SOLAR AIR HEATING
原文传递
导出
摘要 以采用南向壁挂式太阳能空气集热器采暖的实体大实验房为对象,通过实验系统地研究了不同运行工况下混凝土楼板的蓄放热特性对抑制室温波动的影响。同时,在实验的基础上,通过模拟的方法计算分析了基于壁挂式太阳能空气集热器采暖系统作用下不同热质水平及热质的设置位置对室内热环境的影响。研究发现,建筑总热容量越大,室温波动越小,但是当热容量达到一定值后这种影响可忽略。通过正交试验分析得到,围护结构与蓄热楼板热容量的最佳比例是5∶1,蓄热楼板的传热系数越大越好。 The effect of charge/discharge performance of thermal storage slab on shifting indoor temperature swing in difference conditions were experimental investigated by using test room with solar air collector(WSAC) mounted on the south wall. Basing on the experiment results, the effect of design optimization of thermal mass on indoor thermal environment was numerical studied. The results show that the greater building thermal capacity is the less the indoor air temperature swing. However, this effect can be neglected when the capacity were big enough; the best thermal capacity ratio of envelop to thermal storage slab is 5:1 ; the heat transfer coefficient of internal thermal mass is bigger, is better.
出处 《太阳能学报》 EI CAS CSCD 北大核心 2012年第10期1777-1782,共6页 Acta Energiae Solaris Sinica
基金 国家自然科学基金(50778032) 国家"十一五"科技支撑子课题(2006BAA04B04)
关键词 太阳能空气采暖 蓄热楼板 热容量 热稳定性 solar air heating thermal storage slab heat capacity thermal stability
  • 相关文献

参考文献11

  • 1Maloney J, Wang T, Chen B, et al. Thermal network predictions of the daily temperature fluctuations in a direct gain room[J]. Solar Energy, 1982, 29(3) : 207-223.
  • 2Gregory Katherine, Moghtaderi Behdad, Sugo Heber, et al. Effect of thermal mass on the thermal performance of various Australian residential constructions systems [ J ]. Energy and Buildings, 2008, 40 (4) : 459-465.
  • 3Yam Jimmy, Li Yuguo, Zheng Zuohuan. Nonlinear coupling between thermal mass and natural ventilation in buildings [J]. International Journal of Heat and Mass Transfer, 2003, 46(7) : 1251-1264.
  • 4Yang Li' na, Li Yuguo. Cooling load reduction by using thermal mass and night ventilation [ J ]. Energy and Buildings, 2008, 40(11 ) : 2052-2058.
  • 5Zhou Junli, Zhang Guoqiang, Lin Yaolin, et al. Coupling of thermal mass and natural ventilation in buildings [J]. Energy and Buildings, 2008, 40(6) : 979-986.
  • 6Corgnati Stefano Paolo, Kindinis Andrea. Thermal mass activation by hollow core slab coupled with night ventilation to reduce summer cooling loads [ J ]. Energy and Buildings, 2007, 42 (9) : 3285-3297.
  • 7Henze Gregor P, Pfafferott Jens, Herkel Sebastian, et al. Impact of adaptive comfort criteria and heat waves on optimal building thermal mass control [ J ]. Energy and Buildings, 2007, 39 (2): 221-235.
  • 8Kossecka Elisabeth, Kosny Jan. Influence of insulation configuration on heating and cooling loads in a continuously used building [ J ]. Energy and Buildings, 2002, 34(4): 321-331.
  • 9BSRIASHRAE Standard 140P, Standard method of test of the evaluation of building energy analysis computer programs [ S ].
  • 10陆耀庆.实用供热空调设计手册[M].北京:中国建筑工业出版社,2007.

共引文献92

同被引文献6

引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部