期刊文献+

不同隙料厚度对全瓷冠适合性的影响 被引量:5

Effect of different luting spaces on marginal fit of all-ceramic crowns
原文传递
导出
摘要 目的研究InLab MC XL系统不同隙料厚度对Cerec Blocs全瓷冠边缘和内部适合性的影响。方法制备右上颌第一磨牙全冠预备体模型并翻制硅橡胶阴模,分别灌制全瓷石膏、超硬石膏预备体模型各30个。30个全瓷石膏预备体用于光学印模采集,获得30个数字化代型并完全随机分为6组分别设置不同隙料厚度值:0(A组)、10(B组)、20(C组)、30(D组)、40μm(E组)和50μm(F组),每组5个。30个超硬石膏预备体用于全瓷冠黏结,经包埋、剖开后,体式显微镜扫描试件剖面。结果 C、D组边缘适合性均介于30~120μm,内部适合性均介于30~300μm。C组与D组冠边缘适合性比较有统计学差异(P<0.05)。C、D组冠内部适合性不均匀,面适合性相对较大。结论当隙料厚度为20、30μm时,全瓷冠的边缘和内部适合性均在临床可接受范围内;30μm的冠边缘适合性优于20μm,但20、30μm的冠面适合性较差。 Objective To determine the effect of different luting spaces on marginal and internal fit of Cerec Blocs all-ceramic crowns in InLab MC XL system.Methods A right maxillary first molar in the standard model was prepared and subsequently replicated into silicone rubber negative mold.Respectively,30 preparations of all-ceramic plaster and die stone were irrigated.Thirty all-ceramic plasters were used for optical impression,and then 30 three-dimensional digital images were obtained and randomly and equally divided into 6 groups,with their luting spaces were set to 0(group A),10(group B),20(group C),30(group D),40(group E) and 50 μm(group F) respectively by computer software.In addition,30 die stones were prepared for bonding of the all-ceramic crowns.After being bonded,embedded and slitted,these specimens were scanned by stereo microscopy.Results The marginal fit was ranging from 30 to 120 μm and the internal one from 30 to 300 μm in groups C and D.There were statistically significant differences between groups C and D in the marginal fit(P〈0.05).The fit of occlusal surface was better than other parts of the internal fit in groups C and D.Conclusion All-ceramic crowns can obtain the marginal and internal fit which meets clinical requirements when luting spaces are 20 and 30 μm.The crowns with luting spaces of 30 μm is better than that with 20 μm in the marginal fit,but both are worse in the fit of occlusal surface than other parts of internal fit.
出处 《第三军医大学学报》 CAS CSCD 北大核心 2012年第20期2090-2093,共4页 Journal of Third Military Medical University
关键词 计算机辅助设计与制作 隙料厚度 全瓷冠 适合性 computer aided design and manufacture luting space all-ceramic crown fit
  • 相关文献

参考文献16

  • 1Grenade C, Mainjot A, Vanheusden A. Fit of single tooth zirconia cop- ings: comparison between various manufacturing processes[ J]. J Pros- thet Dent, 2011, 105(4) : 249 -255.
  • 2Iwai T, Komine F, Kobayashi K, et al. Influence of convergence angle and cement space on adaptation of zirconium dioxide ceramic copings [J]. Acta Odontol Scand, 2008, 66(4) : 214 -218.
  • 3Komine F, lwai T, Kobayashi K, et al. Marginal and internal adapta- tion of zirconium dioxide ceramic copings and crowns with different fin- ish line designs[J]. Dent Mater J, 2007, 26(5) : 659 -664.
  • 4Quintas A F, Oliveira F, Bottino M A. Vertical marginal discrepancy of ceramic copings with different ceramic materials, finish lines, and luting agents : an in vitro evaluation [ J ]. J Prosthet Dent, 2004, 92 (3) : 250 - 257.
  • 5Gonzalo E, Suarez M J, Serrano B, et al. A comparison of the margin- al vertical discrepancies of zirconium and metal ceramic posterior fixed dental prostheses before and after cementation [ J ]. J Prosthet Dent, 2009, 102(6) : 378 -384.
  • 6Carter S M, Wilson P R. The effect of die-spacing on crown retention [J]. Int J Prosthodont, 1996, 9(1) : 21 -29.
  • 7Bindl A, Mormann W H. Fit of all-ceramic posterior fixed partial den- ture frameworks in vitro [ J ]. Int J Periodontics Restorative Dent, 2007, 27(6) : 567 -575.
  • 8Rastogi A, Kamble V. Comparative analysis of the clinical techniques used in evaluation of marginal accuracy of cast restoration using ste- reomicroscopy as gold standard [ J ]. J Adv Prosthodont, 2011, 3 (2) : 69 - 75.
  • 9Barnes D, Gingell J C, George D, et al. Clinical evaluation of an all- ceramic restorative system: a 36-month clinical evaluation [ J ]. Am J Dent, 2010, 23(2) : 87 -92.
  • 10Kassem A S, Atta O, E1-Mowafy O. Survival rates of porcelain molar crowns-an update[ J]. Int J Prosthodont, 2010, 23 ( 1 ) : 60 - 62.

二级参考文献13

  • 1Allen K L, Schenkel A B, Estafan D. An overview of the CEREC 3D CAD/CAM system[J]. Gen Dent, 2004, 52(3) : 234-235.
  • 2Mormann W H. The evolution of the CEREC system [ J ]. J Am Dent Assoc, 2006, 137 Suppl: 7S- 13S.
  • 3Kurbad A, Reichel K. InEOS-new system component in Cerec 3D [J]. IntJComputDent, 2005, 8(1): 77 -84.
  • 4Mehl A, Ender A, Mormann W, et al. Accuracy testing of a new intraoral 3D camera [J]. Int J Comput Dent, 2009, 12( 1 ) : 11 -28.
  • 5Persson A S, Andersson M, Oden A, et al. Computer aided analysis of digitized dental stone replicas by dental CAD/CAM technology[J]. Dent Mater, 2008, 24(8): 1123- 1130.
  • 6Persson A S, Oden A, Andersson M, et al. Digitization of simulated clinical dental impressions : virtual three-dimensional analysis of exactness[J]. Dent Mater, 2009, 25(7) : 929 -936.
  • 7Mou S H, Chai T, Wang J S, et al. Influence of different convergence angles and tooth preparation heights on the internal adaptation of Cerec crowns [J]. J Prosthet Dent, 2002, 87(3) : 248 -255.
  • 8Pfeiffer J. Dental CAD/CAM technologies: the optical impression (I) [J]. Int J Comput Dent, 1998, 1(1) : 29 -33.
  • 9Luthardt R G, Bomemann G, Lemelson S, et al. An innovative method for evaluation of the 3-D internal fit of CAD/CAM crowns fabricated after direct optical versus indirect laser scan digitizing [ J]. Int J Prosthodont, 200d, 17(6): 680-685.
  • 10Vollbrecht J. Sirona CEREC Blocs and inCoris [ J]. Int J Comput Dent, 2007, 10(1): 127-134.

共引文献6

同被引文献47

  • 1陈丽萍,华楠,葛艳,庄晶,钱琼.不同牙冠高度与全冠固位力关系的实验分析[J].上海口腔医学,2004,13(4):308-311. 被引量:7
  • 2Abdulredh A. Applying microwave technology to sintering dental zir-conia[J].Journal of Prosthetic Dentistry,2012.304-309.
  • 3赵铱民.口腔修复学[M]北京:人民卫生出版社,200887-88.
  • 4American Dental Association. ANSI/ADA Specification n°8 for zinc phosphate cement[A].Chicago:American Dental Association,1971.
  • 5Effrosyni A Tsitrou,Simon E Northeast,Richard van Noort. Evalua-tion of the marginal fit of three margin designs of resin[J].Journal of Dentistey,2007.68-73.
  • 6Y Kokubo,C Ohkubo,M Tsumita. Clinical marginal and internal gaps of procera all ceram[J].Journal of Oral Rehabilitation,2005.526-530.
  • 7McLean JW,von Fraunhoffer JA. The estimation of cement film thickness by an in vivo technique[J].British Dental Journal,1971.107-111.
  • 8Mirza Rustum Baig. A Keson Beng-Choon Tan,Evaluation of the marginal fit of a zirconia ceramic computer-aided machined(CAM) crown system[J].Journal of Prosthetic Dentistry,2010.216-227.
  • 9MA Janney,HD Kimery. Microwave sintering of alumina at 28 GHz[J].Ceramic Powder Science,1988.919-924.
  • 10王泉,张建中.Cerec全瓷修复体适合性的研究进展[J].山东医药,2008,48(14):150-151. 被引量:11

引证文献5

二级引证文献13

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...