期刊文献+

南京热电厂400t/h锅炉燃烧调整试验及分析 被引量:2

Debugging and Analysis of 400 t/h Boiler Combustion in Nanjing Cogeneration Power Plant
在线阅读 下载PDF
导出
摘要 针对南京热电厂6号炉长期存在的飞灰含碳量偏高等问题,进行了6号炉燃烧调整试验;分析各种因素对锅炉运行安全性和经济性的影响,从中确定最佳运行方式,并提出改善锅炉运行性能的具体措施和建议。 Higher carbon content in fly ash was a long-standing problem on No.6 boiler of Nanjing Cogeneration Power Plant. For this reason the combustion dehuggings and testings on No.6 boiler were carried out; and the impacts of various factors on the safety and economics of boiler operation were analyzed. Thus the optimum operation mode was therefrom determined, and the specific measures and recommendations on improving operation performance of boiler were put for ward.
出处 《中国电力》 EI CSCD 北大核心 2000年第6期11-13,共3页 Electric Power
关键词 锅炉 旋流燃烧器 燃烧调整 热电厂 boiler vortex burner combustion debugging
  • 相关文献

同被引文献3

  • 1岑可法.锅炉燃烧试验研究方法及测量技术[M].北京:水利电力出版社,1985..
  • 2冯俊凯 沈幼庭.锅炉原理及计算[M].北京:科学出版社,1995..
  • 3岑可法.锅炉燃烧试验研究方法及测量技术[M].北京:水利电力出版社,1985..