期刊文献+

万向椎弓根螺钉在脊柱畸形后路矫正中的应用

The Application of Polyaxial Pedicle Screw in Posterior Correction of Spine Deformity
暂未订购
导出
摘要 目的分析和总结万向椎弓根螺钉在脊柱畸形后路矫正中的矫正方法及矫正效果。方法应用万向椎弓根螺钉治疗各种脊柱畸形17例,术前使用多种方法减轻脊柱畸形程度,术中强调使用原位转钉等方法矫正脊柱三维畸形。测量术前及术后脊柱主要结构性侧凸平均Cobb角;测量术前及术后脊柱矢状面胸段、胸腰段和腰段的角度,判断脊柱矢状面是否正常化;采用椎弓根标记法测量术前及术后顶椎椎体旋转程度(除外3例顶椎全切病例)。记录有无内固定并发症。结果术前脊柱主要结构性侧凸平均Cobb角63.18°,术后平均25.35°,秩和T=153.00,P<0.005,差异有显著性。矢状面异常的15例病例术后复片显示矢状面正常化。顶椎椎体旋转(除外3例顶椎全切病例),术前Ⅰ度3例,术后均为0度,余病例均有不同程度的旋转畸形残留。所有病例无重要血管、神经损伤,无内置物松动、滑脱或断裂。结论万向椎弓根螺钉可以简化脊柱畸形的操作,增加安全性,同时可以取得良好的矫正效果。 【Objective】 To analyze and summarize the correction methods and effects of polyaxial pedicle screw in posterior correction for spine malformation.【Methods】 Polyaxial pedicle screws were used in treating 17 cases of spine deformity of various types.Methods were used to reduce the degrees of spine deformity before the operation and methods including screw-rotating in situ were strongly recommended in spine 3-d deformity correction.The average Cobb angle of main structural scoliosis was measured before and after the operation respectively.The angles of thoracic segment,thoracolumbar segment were measured before and after the operation respectively.Pedicle markers were used to measure the top vertebrae rotation before and after the operation respectively(excluding the 3 cases of apical vertebrectomy).Complications resulted from internal fixation were carefully observed and recorded.【Results】 The pre-operative average Cobb angle of main structural scoliosis was 63.18.while the post-operative one was 25.35.The rank-sum T=153.00 and P 0.005 suggests the difference is statistically significant.Post-operative X-ray exam showed he 15 cases of abnormal sagittal plane were normalized.Among the 15 cases receiving top vertebral rotation,3 cases of grade I were improved to grade 0 while rotation deformity of various degrees were still observed in the rest cases.No important vascular or neural injury,no loosened,slippage,or broken inserters were found in all cases.【Conclusion】 Polyaxial pedicle screw can simplify spine deformity correction,increase the safety while achieving good correction effect.
出处 《中国现代医学杂志》 CAS CSCD 北大核心 2012年第24期60-63,共4页 China Journal of Modern Medicine
关键词 万向椎弓根螺钉 脊柱畸形 置棒 原位转钉 平衡 脊椎切割 polyaxial pedicle screw spine deformity inserter screw-rotation in situ balance spine cutting
  • 相关文献

参考文献10

二级参考文献20

  • 1邱贵兴,徐宏光,王以朋,沈建雄,翁习生,仉建国,赵宇.青少年特发性脊柱侧凸术后失代偿原因分析及处理[J].中华骨科杂志,2003,23(7):414-417. 被引量:24
  • 2殷渠东,郑祖根,王以进.斜钉效应在胸腰椎爆裂骨折复位固定中的价值探讨[J].医用生物力学,1993,8(2):108-111. 被引量:3
  • 3Polly DW, Orchowski JR, Ellenbogen RG. Revision pedicle screws:bigger,longer shim-what is best?Spine,1998,23:1374-1379.
  • 4Yerby SA,Toh E,Mclain RF.Revision of failed pedicle screws using hydroxyapatite cement:a biomechanical analysis.Spine,1998,23:1657-1661.
  • 5Buhler DW,Berlemann U,Oxland TR,et al.Moments and forces during pedicle screw insertion:in vitro and in vivo measurements.Spine,1998,23:1220-1228.
  • 6Krag MH,Beynnon BD,Pope MH,et al.An internal fixation for posterior application to short segments of the thoracic,lumbar or lumbosacral spine:design and testing.Clin Orthop,1986,203:75-93.
  • 7Stanford RE,Loefler AH,Stanford PM,et al.Multiaxial pedide screw designs:static and dynamic mechanical testing[J].Spine,2004;29(4):367.
  • 8Fogel GR,Reitman CA,Liu W,et al.Physical Characteristics of polyaxial-headed pedicle screws and biomechanical comparison of load with their failure[J].Spine,2003; 28(5):470.
  • 9Shepard MF,Davies MR,Abayan A,et al.Effects of polyaxial pedicle screws on lumbar construct rigidity[J].J Spinal Disord Tech,2002; 15 (3):233.
  • 10Lindsey C,Deviren V,Xu Z,et al.The effects of rod contouring on spinal construct fatigue strength[J].Spine,2006;31(15):1680.

共引文献24