摘要
对R410A家用空调系统中油分离器的回油毛细管,选择不同规格进行对比试验研究。试验结果表明,在制冷量为7200w的R410A家用空调系统中,主毛细管流量与回油毛细管流量之比为5.5%时,能较好的满足系统要求。
This paper makes experimental comparison investigation on oil separator' s oil return capillary tube with different size for R410A domestic air conditioning. The result shows that it is suitable for air conditioning in capacity of 7200W using R410A as refrigerant when the ratio of the flow of main capillary tube divided by the flow of oil return capillary tube is 5.5%.