期刊文献+

回油毛细管在R410A家用空调系统中的应用研究 被引量:5

回油毛细管在R410A家用空调系统中的应用研究
在线阅读 下载PDF
导出
摘要 对R410A家用空调系统中油分离器的回油毛细管,选择不同规格进行对比试验研究。试验结果表明,在制冷量为7200w的R410A家用空调系统中,主毛细管流量与回油毛细管流量之比为5.5%时,能较好的满足系统要求。 This paper makes experimental comparison investigation on oil separator' s oil return capillary tube with different size for R410A domestic air conditioning. The result shows that it is suitable for air conditioning in capacity of 7200W using R410A as refrigerant when the ratio of the flow of main capillary tube divided by the flow of oil return capillary tube is 5.5%.
出处 《日用电器》 2012年第8期68-71,共4页 ELECTRICAL APPLIANCES
关键词 压缩机 回油 R410A 回油毛细管 compressor oil return r41OA oil return capillary tube
  • 相关文献

参考文献4

  • 1Ebisu,T.etaI.Heat transfer characteristics and correlations for R410A flowing inside a horizontal smooth tube.ASHRAE Transaction, 1998(I) :556-561.
  • 2American Society of Heating, Refrigerating and Air- Conditioning Engineers [EB/OL], http://www.ashrae.org/.
  • 3GB/T23137-2008,家用和类似用途热泵热水器[S].北京:北京标准出版社,2008.
  • 4杨传波,张薇,郭漪,李连生.制冷系统含油量对制冷压缩机工作性能影响的理论分析和实验研究[J].制冷学报,2005,26(2):19-23. 被引量:37

二级参考文献6

  • 1Shao D.W, Granryd E. Heat transfer and pressure drop of HFC134a-oil mixture in a horizontal condensing tube. International Journal of Refrigeration, 1995,18 (8): 524-533.
  • 2M. Youbi-Idrissi, J. Bonjour, C. Marvillet, F. Meunier. Impact of refrigerant-oil solubility on an evaporator performances working with R-407C.International Journal of Refrigeration, 2003,26(3): 284-292.
  • 3O. Lottin, P. Guillemet, Jean-Marc Lebreton. Effects of synthetic oil in a compression refrigeration system using R410A. Part I: modelling of the whole system and analysis of its response to an increase in the amount of circulating oil.International Journal of Refrigeration , 2003,26(7): 772-782.
  • 4B·T·叶姆采夫 关醒凡 于华译.工程流体力学[M].北京:高等教育出版社,1990..
  • 5Yu Chen. Mathematical modeling of scroll compressors-partⅠ: compressor process modeling.Nils P. Halm, Eckard A. Groll, James E. Braun.International Journal of Refrigeration , 2002,25(6): 731-750.
  • 6邢子文,彭学院,束鹏程.R134a螺杆制冷压缩机的泄漏特性研究[J].制冷学报,2000,21(4):23-28. 被引量:24

共引文献37

同被引文献28

引证文献5

二级引证文献6