期刊文献+

头位照相法与量角器法测量代偿头位的比较研究 被引量:3

Comparison between photographic analysis and orthopedic goniometer of measurement of compensatory head posture
原文传递
导出
摘要 目的探讨相对参照点头位照相法和骨科量角器法在临床测量代偿头位角度的应用,并比较两种方法的特点。方法随机数字表法选择2011年3至4月及8至9月于天津市眼科医院住院治疗的有代偿头位患者30例,分别采用头位照相法和骨科量角器法先后测量患者头位在3个轴向(矢状轴、垂直轴、水平轴)扭转的角度。采用配对t检验统计方法比较两种方法测量的结果。结果头位照相法测量代偿头位扭转角为15.62°±7.48°;骨科量角器法测量代偿头位扭转角为15.50°±6.99°,两种方法测量结果之间积矩相关系数r=0.955(P〈0.01),差异无统计学意义(t=0.286,P=0.777)。结论相对参照点头位照相法和骨科量角器法操作简便,是适合临床应用的测量代偿头位的方法。两种方法测量代偿头位扭转角度结果一致性好。 Objective To evaluate the application of relative reference point photographic analysis method and goniometer method for head posture measurement, and compare the characteristics of the two methods. Methods Thirty patients from March 2011 to April 2011 and August to September with AHP in our hospital were recruited. The AHP were measured by photographic analysis and goniometer method respectively. The data were analyzed by SPSS software. Results The mean AHP was 15.62°± 7.48° by photographic analysis measurement, 15.50°± 6. 99° by goniometer measurement. The Pearson's correlation coefficient( r = 0. 955, P 〈 0. 001, t = 0. 286, P = 0. 777 ) . Conclusions Relative reference point photographic analysis is a simple and effective way to measure AHP. The results measured by the two methods are highly consistent.
出处 《中华眼科杂志》 CAS CSCD 北大核心 2012年第9期789-793,共5页 Chinese Journal of Ophthalmology
基金 天津市卫生局科技基金项目(2011ky33)
关键词 体位 摄影术 斜视 诊断技术 眼科 Posture Photography Strabismus Diagnostic techniques,ophthalmological
  • 相关文献

参考文献20

  • 1Rosenbaum AL, Santiago AP. Clinical strabismus management. Philadelphia: WB Saunders, 1999:19.
  • 2Cooper EL, Sauidall GS. Surgical treatment of congenital nystagmus. Arch Ophthalmol, 1969,81:473-480.
  • 3Sradj N. Uber die Bedeutung ocular bedingter Zwangs-hahungen und die Moglichkeit ihrer Messung mit dem Torticollometer. Klin Monatsbl Augenheilk, 1974, 1656:823.
  • 4Sradj A: Torticollometry for direct measurement of head position. Am Orthopt J, 1984, 34:117.
  • 5Mitchell PR, Wheeler MB, Parks MM. Kestenbaum surgical procedure for torticollis secondary to congenital nystagmus. J Pediatr Ophthalmol Strabismus, 1987,24:87-92.
  • 6Barbe ME, Scott WE, Kutschke PJ. A simplified approach to the treatment of Duane's syndrome. Br J Ophthalmol, 2004,88 : 131- 138.
  • 7Lau FH, Fan DS, Sun KK, et al. Residual torticollis in patients after strabismus surgery for congenital superior oblique palsy. Br J Ophthalmol, 2009,93:1616-1619.
  • 8Rosenbaum AL, Santiago AP. Clinical strabismus management. Philadelphia : WB Saunders, 1999 : 19-20.
  • 9Patrik K, Jirl H. Non-contact method for measurement of head posture by two cameras and calibration means. Trends Biomedical Engineering Bra Tisla VA, 2009 : 16-18.
  • 10Spierer A, Barak A. Measurement of head-turn in ocular torticollis. Ophthalmic Surg Lasers, 1997 May,28:424-425.

二级参考文献8

共引文献4

同被引文献31

  • 1冯雪亮,张树梅,李俊红.上斜肌腱缝线延长术[J].中国实用眼科杂志,2005,23(10):1134-1136. 被引量:8
  • 2Kushner BJ. The usefulness of the cervical range of motion device in the ocular motility examination[J]. Arch Ophthahnol. 2000,118(7) :946-950.
  • 3Holmes JM, Leske DA, Kupersmitll MJ. New methods tbr quantifying diplopia[J]. Ophthalmology, 2005 , 112 ( 11 ) : 2035- 2039.
  • 4Jellema HM, Merekel-Timmer E, Kloos R, el ai. Quality of life improves after strabismus surgery in patients v,'ith Graves' Orbilopathy[J], Eur J Endocrino1,2014,170(5) :785-789.
  • 5Rowe FJ, Hanif S. Unioeular and binocular fields of rotation measures: Octopus versus Goldmann[J]. Graefes Arch Clin Exit Ophthalmol. 2011,249 ( 6 ) : 909-919.
  • 6Hatt SR. Leske DA. Holmes JM. Comparing methods to quantify diplopia[J]. Ophthalmology ,2007,114( 12 ) :2316-2322.
  • 7Malta NS, Singman EL, Christoff A, el al. The matta map: a new method of measuring incomitant strabismus[J]. Am Orthopt J, 2008.58 : 88-91.
  • 8Kenneth Wright. 斜视手术彩色图谱——策略与技巧[M]. 杨士强译. 3版. 北京:北京大学医学出版社,2013:59-60.
  • 9赫雨时,张允和,赵堪兴. 上、下直肌移植术对外直肌麻痹疗效的探讨[J]. 中华眼科杂志,1978,14(5):96-100.
  • 10Mehendale RA, Dagi LR, Wu C,et al. Superior rectus transposition and medial rectus recession for Duane syndrome and sixth nerve palsy[J]. Arch Ophthalmol,2012,130(2):195-201.

引证文献3

二级引证文献8

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部