期刊文献+

Supreme喉罩和气管插管在全身麻醉应用中的对比研究 被引量:15

Comparative study of laryngeal mask airway Supreme and tracheal intubation applicated in general anesthesia
暂未订购
导出
摘要 目的比较Supreme与气管插管对围术期血流动力学及并发症的影响。方法选取年龄35~60岁,ASA分级为Ⅰ~Ⅱ级,拟在全身麻醉下行乳癌根治术的患者50例,随机分为Supreme组(S组,n=25)和气管插管组(T组,n=25)。观察Su-preme喉罩试插次数、对位程度、气道峰压,记录麻醉诱导前后、置入喉罩或插入气管导管即刻、插入后1、3、5min、拔管前即刻及拔管后1、3、5min的心率和血压,并观察术后24h内是否发生咽喉疼痛、吞咽异物感和声嘶。结果 Supreme喉罩一次性置入成功率为92%,且对位程度均较好,二氧化碳分压维持在正常范围。与T组比较,S组气道压明显下降。与诱导前基础值比较,两组诱导后心血管指标均明显下降(P<0.05)。T组插管即刻、插管后1、3min、拔管前即刻和拔管后1、3、5min的指标较基础值显著升高(P<0.05)。S组插管后3、5min血压较诱导后水平显著降低(P<0.05),拔出前即刻和拔后1、3、5min的指标与基础值比较差异无统计学意义。与S组比较,T组插管即刻、拔管前即刻、插管后和拔管后1、3、5min的指标均明显升高,其他时间点各指标两组间比较差异均无统计学意义(P>0.05)。与T组比较,S组气道并发症明显降低(P<0.05)。结论 Supreme喉罩置入一次性成功率较高,可减轻围术期心血管应激反应,降低气道并发症,提高患者全身麻醉后的舒适度。 Objective To investigate the effects of Supreme LMA application and endotracheal intubation on hemodynamics during induction of or emergency from general anesthesia and postoperative complications. Methods Fifty patients of 35-- 60 years old, ASA physical status I -- II , scheduled for selective modified radical masteetomy under general anesthesia were randomly divid- ed into Supreme(S,n=25) and tracheal intubation(T ,n= 25) groups. The attempts of intubation,airway pressure,systolic or diastolic arterial pressure,and heart rate(HR) were recorded during the induction of or emergency from general anesthesia. Then sore throat,dysphagia and trachyphonia were observed within 24 h postoperatively. Results The success rate of the first attempt insertion of Supreme was 92 %. Compared with group T, airway pressure was significantly decreased in group S(P〈 0.05). Compared with basal value, systolic and diastolic pressures and heart rate were significantly increased during intubation and extubation in group T,which were also much higher than those in group S(P〈0.05). The incidence of pharyngolaryngeal adverse events after extubation within 24 h were significantly decreased in group S than that in group T(P〈0.05). Conclusion Insertion Supreme LMA can be easily managed,induces less hemodynamic changes,and can improve patients comfort after general anesthesia.
出处 《重庆医学》 CAS CSCD 北大核心 2012年第29期3061-3063,共3页 Chongqing medicine
关键词 喉面罩 插管法 气管内 心血管反应 并发症 laryngeal masks intubation, intratracheal cardiovascular response complication
  • 相关文献

参考文献14

  • 1Esehertzhuber S,Brimacombe J, Hohlrieder M, et al. The laryngeal mask airway Supreme a single use laryngeal mask airway with an oesophageal vent. A randomised, cross-over study with the laryngeal mask airway ProSeal in paralysed, anaesthetised patients [J]. Anaesthesia, 2009,64(1) :79-83.
  • 2岳云,田鸣,左明章,等主译.喉罩麻醉原理与实践[M].2版.北京:人民卫生出版社,2006:264.
  • 3Joffe AM, Liew EC. Intubation through the LMA-Supreme..a pilot study of two techniques in a manikin[J]. Anaesth Intensive Care, 2010,38 (1) : 33-38.
  • 4Wong DT, Yang JJ, Jagannathan N. Brief review: The LMA SupremeTM supraglottic airway[J]. Can J Anaesth,2012,59(5):483-493.
  • 5Sharma V, Verghese C, McKenna PJ. Prospective audit on the use of the LMA-Supreme for airway management of adult patients undergoing elective orthopaedic surgery in prone position[J]. Br J Anaesth,2010,105(2) :228-232.
  • 6Adachi YU, Takamatsu I, Watanabe K, et al. Evaluation of the cardiovascular responses to fiberoptic orotracheal intubation with television monitoring:comparison with conventional direct laryngoscopy[J]. J Clin Anesth,2000, 12(7) :503-508.
  • 7Verghese C, Ramaswamy B. LMA-Supreme-a new singleuse LMA with gastric access:a report on its clinical efficacy[J]. Br J Anaesth, 2008,101 (3) : 405-410.
  • 8Seet E,Rajeev S,Firoz T,et al. Safety and efficacy of la ryngeal mask airway Supreme versus laryngeal mask air way ProSeal:a randomized controlled trial[J]. Eur J An aesthesiol, 2010,27 (7) : 602-607.
  • 9Timmermann A, Cremer S, Eich C, et al. Prospective clinical and fiberoptic evaluation of the Supreme laryngeal mask airway[J]. Anesthesiology,2009,110(2):262-265.
  • 10Jagannathan N, Sohn LE,Chang E. A cohort evaluation of the laryngeal mask airway-supremeTM in children[J]. Pae- diatr Anaesth,2012,15(2) :268-269.

共引文献6

同被引文献109

  • 1袁莉,王世端,阎玮,殷积慧,刘陕岭,黄辉.右美托咪啶对高血压患者麻醉诱导期间血流动力学稳定性的影响[J].中华临床医师杂志(电子版),2011,5(23):7092-7095. 被引量:34
  • 2王立中,刘雪梅.喉罩应用于腹腔镜手术患者麻醉的临床分析[J].中国医学前沿杂志(电子版),2013,5(12):52-55. 被引量:5
  • 3龙跃,李准民,易礼清,彭家宽,邹最,彭捷.硬膜外复合喉罩全麻在重症肌无力患者胸腺切除术中的应用[J].第二军医大学学报,2007,28(10):1152-1153. 被引量:4
  • 4Miller DM,Camporota L. Advantages of ProSeal and SLIPA airways over tracheal tubes for gynecological laparoscopies[J].Canadian Journal of anaesthesia-Journal canadien d anesthesie,2006,(02):188-193.
  • 5Lange M,Smul T,Zimmermann P. The effectiveness and patient comfort of the novel streamlined pharynx airway liner(SLIPA)compared with the conventional laryngeal mask airway in ophthalmic surgery[J].Anesthesia and Analgesia,2007,(02):431-434.
  • 6SooHoo NF, Farng E, Chambers L, et al. Comparison ofcomplication rates between hemiarthroplasty and total hiparthroplasty for intracapsular hip fractures. Orthopedics.2013;36(4):e384-389.
  • 7Das S, Gupta SD, Goswampi A, et al. Comparative study ofheart rate responses to laryngoscopic endotracheal intubationand to endotracheal intubation using intubating laryngealmask airway under general anaesthesia in patients with puremitral stenosis for closed mitral commissurotomy. J IndianMed Assoc. 2013; 111 (4):239-40,242-4.
  • 8Sulaiman S, Karthekeyan RB, Vakamudi M, et al. The effectsof dexmedetomidine on attenuation of stress response toendotracheal intubation in patients undergoing electiveoff-pump coronary artery bypass grafting. Ann Card Anaesth.2012;15(1):39-43.
  • 9Choyce A, Avidan MS, Harvey A, et al. The cardiovascularresponse to insertion of the intubating laryngeal mask airway.Anaesthesia. 2002;57(4):330-333.
  • 10Feferman T, Im SH, Fuchs S, et al. Breakage of tolerance to hidden cytoplasmic epitopes of the acetylcholine recep- tor in experimental autoimmune myasthenia gravis[J] . Neuroimmunoi, 2003,140 (1/2) :153-158.

引证文献15

二级引证文献65

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部