摘要 完全自动化的低压供配电系统是电力系统发展的趋势,而监控管理系统在低压供配电系统自动化中起着举足轻重的作用,但出于成本因素、安全因素以及可靠性因素考虑,低压供配电监控管理系统应用普及率并不高,本文在对CCLink-LT现场总线的研究基础上,从控制策略、安全可靠、实效经济等方面,对基于CCLink-LT总线的低压供配电监控管理系统的应用可行性进行分析,通过理论性研究,证明该系统其具有较好的安全性,较高的可靠性和性价比,及应用可行性. The trend for power system development is the highly automated low voltage power supply system, in which the monitoring management system plays an important role. However, due to the factors such as cost, reliability and safety, the low voltage power supply monitoring management system is not widely applied. Based on the study of CCLink-LT bus, the article analyzed feasibility of CCLink-LT bus for the low voltage distribution monitoring management from different aspects. It is pointed out that this system is characterized by its safety, reliability, cost-effectiveness and feasibility, and offers a new approach to low voltage power supply monitoring management system.
作者 邓松 张迎辉
出处 《深圳职业技术学院学报》 CAS 2012年第5期31-34,共4页 Journal of Shenzhen Polytechnic
关键词 CCLink—LT 低压供配电 断路器 可行性 CCLink-LT low voltage power supply and distribution switch feasibility
  • 相关文献

参考文献3

  • 1CC-Link协会中文网.http://www.cc-link.org.crdcc-link/cclinklt/339.shtml[OL].上海:中国自动化学会集成自动化技术专业委员会控制与通讯CC-Link工作组,2012.
  • 2中华人民共和国国家标准化指导性技术文件.控制与通讯总线CC-Link规范[S].北京:中国标准出版社,2005.
  • 3邓松,阮龙德.低压供配电系统后台管理的研究和实施[J].电工技术,2008(2):5-8. 被引量:1

二级参考文献6

  • 1周明.现场总线控制[M].北京:中国电力出版社,2001..
  • 2阳宪惠 等.现场总线技术及应用[M].北京:清华大学出版社,1996.238-306.
  • 3FX2N-16CCL CC-Link系统主站模块FX2N-16CCLCC-Link接口模块用户手册
  • 4开放式现场总线CC-Link、CC-Link/LT产品样本,2006
  • 5FX3U.FX3UC系列微型可编程控制器编程手册.2006
  • 6张祥军.工厂变配电技术.北京:中国劳动社会保障出版社,2007