摘要 目的通过体外实验研究观察结核杆菌和不同内植物材料的黏附情况,并与表皮葡萄球菌进行对照,探讨脊柱结核行病灶清除后植入内固定的安全性问题。方法以表皮葡萄球菌为对照,将临床常见的不同内植物材料(不锈钢,钛,钛合金)置入结核杆菌、表皮葡萄球菌的菌液,行细菌培养后通过扫描电镜观察比较不同细菌对不同材料的黏附情况,统计分析结果。结果结核杆菌相对于同一种材料的黏附数量均较表皮葡萄球菌少(P<0.01),而在不同材料的结核杆菌黏附比较中,钛及钛合金的细菌黏附数量少于不锈钢(P<0.01)。结论在脊柱结核患者体内植入内固定是相对安全的,内固定材料选用钛或钛合金优于不锈钢。 Objective To study the adhesion of Mycobacterium tuberculosis onto the surface of different implant materials in vitro,and to evaluate the safety of internal fixation implants in spinal tuberculosis through comparison with Staphylococcus epidermidis.Methods Staphylococcus epidermidis was selected as the control.Common implant materials(stainless steel,titanium and titanium alloy) were individually placed in the different bacterial suspensions and the adherence of Mycobacterium tuberculosis and Staphylococcus epidermidis onto the different implant materials was observed by scanning electron microscopy(SEM)after bacterial culture.Results The adherence of Mycobacterium tuberculosis onto the surface of each material significantly decreased compared with Staphylococcus epidermidis(P〈0.01).The number of Mycobacterium tuberculosis adhered onto the surface of pure titanium or titanium alloy significantly decreased compared with stainless steel(P〈0.01).Conclusion Instrumentation surgery is relatively safe in patients with spinal tuberculosis.As the implant materials,titanium alloy and pure titanium are superior to stainless steel for internal fixation.
出处 《实用临床医学(江西)》 CAS 2012年第8期1-3,6,共4页 Practical Clinical Medicine
基金 江西省卫生厅普通科技计划(20093217)
关键词 脊柱结核 内固定物 结核杆菌 黏附 spinal tuberculosis; implant materials internal fixation implants; mycobacterium tuberculosis; adhesion
  • 相关文献

参考文献6

二级参考文献8

  • 1Sundararaj GD,Behera S,Ravi V,et al.Role of posterior stabilisation in the management of tuberculosis of the dorsal and lumbar spine[J].J Bone Joint Surg[Br],2003,85(1):100-106.
  • 2Yilmaz C,Selek HY,Gurkan I,et al.Anterior instrumentation for the treatment of spinal tuberculosis[J].J Bone Joint Surg(Am),1999,81(9):1261.
  • 3Govender S.The outcome of allografts and anterior instrumentation in spinal tuberculosis[J].Clin Orthop,2002,398:60-66.
  • 4Naylor pt,Myrvik QN,Gristina AG.Antibiotic resistance of biomaterialadherent coagulase-negative and coagulase-positive staphylococci[J].Clin Orthop Related Research,1990,261:126-133.
  • 5Oga M,Arizono T,Takasita M,et al.Evaluation of the risk of instrumentation as a foreign body in spinal tubercul-osis:clinical and biologic study[J] Spine,1993,18(13):1890-1894.
  • 6黄云超,张尔永,石应康,田子朴,周清华,雷蕾,贾文祥.人工心脏瓣膜材料细菌粘附的体外实验[J].生物医学工程学杂志,1999,16(4):406-410. 被引量:6
  • 7金大地,陈建庭,张浩,瞿东滨,王吉兴,江建明.一期前路椎体间植骨并内固定治疗胸腰椎结核[J].中华外科杂志,2000,38(12):900-902. 被引量:415
  • 8周劲松,陈建庭,金大地,刘金标.结核分枝杆菌对材料粘附能力的体外实验研究[J].中国脊柱脊髓杂志,2003,13(11):670-673. 被引量:119

共引文献30

同被引文献91

引证文献5

二级引证文献24

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部