摘要 比较了ARI标准空调工况与中国名意空调工况的差异 ,从制冷循环和传热的角度分析了工况差异对蒸气压缩式水冷冷水机组满负荷效率的影响。指出选用冷水机组时必须重视工况不同对冷水机组性能产生的影响 ,考虑并满足中国气候和水质条件的要求 。 Compares the difference between the stipulations in the ARI standard and the actual air conditioning performance under the special conditions in China. Through a compression refrigeration and heat transfer analysis, evaluates the drop in full load efficiency of water cooled liquid chillers from that according to the ARI standard, and concludes that the chiller selected in China should meet the local weather and water quality requirements to ensure the chillers long term operating efficiency and reliability.
作者 卫宇
出处 《暖通空调》 北大核心 2000年第4期67-69,72,共4页 Heating Ventilating & Air Conditioning
关键词 ARI标准 空调工况 水冷冷水机组 满负荷效率 ARI standard, air conditioning performance, water cooled liquid chiller, compression refrigeration, full load efficiency
  • 相关文献

参考文献9

  • 1ARI Standard550-1992. Centrifugal and rotary water-chilling packages. Air-Conditioning andRefrigeration Institute, 4301 North Fairfax Drive,Suite 425, Arlington, Va 22203, USA.
  • 2ARI Standard 550-1992. Positive displacement compressor water-chilling packages.Air-Conditioning and Refrigeration Institute, 4301 North Fairfax Drive,Suite 425,Arlington, Va 22203, USA.
  • 3ARI Standard 550/590-1998. Water-chilling packages using the vapor compressioncycle. Air-Conditioning and Refrigeration Institute, 4301 North Fairfax Drive,Suite 425,Arlington, Va 22203, USA.
  • 4JB/T7666-1995.制冷和空调设备名义工况一般规定.
  • 5JB/T3355-1991.离心式冷水机组技术条件.
  • 6GB7190.1/2-1997.玻璃纤维增强塑料冷却塔.
  • 7ARI Guideline E-1988. Fouling factors:A survey of their application in today’sair-conditioning and refrigeration industry. Air-Conditioning and Refrigeration Institute,1501 Wilson Boulevard, Arlington, Va 22209, USA.
  • 8ARI Guideline E-1997. Fouling factors: A survey of their application in today’sair-conditioning and refrigeration industry. Air-Conditioning and Refrigeration Institute,4301 North Fairfax Drive, Suite 425, Arlington, Va 22203, USA.
  • 9Studies show how air-conditioning equipment efficiency has increased, Tech. Update,Research and Technology News from ARI, Koldfax, Oct 1997. 稿件修回日期:2000-06-28

同被引文献42

  • 1杨开明.(火用)分析应用初探[J].四川电力技术,1993,16(2):26-31. 被引量:1
  • 2王志毅,陈光明,沈智广,方建良,谷波.深井水源热泵制热变工况实验模拟分析[J].制冷与空调,2005,5(3):71-73. 被引量:3
  • 3清华大学建筑节能研究中心.中国建筑节能年度发展研究报告[M].北京:中国建筑工业出版社,2009.
  • 4ARI Standard 550/590-98,Standard for Water Chilling Packages Using the Vapor Compression Cycle,1998,AirConditioning and Refrigeration Institute,4301 North Fairfax Drive,Suite 425,Arlington,Va.22203,U.S.A.
  • 5南赋 夏清 于航.节能,2001,(2):15-18.
  • 6胡益雄 袁锋.长沙铁道学院学报,2001,19(4):60-64.
  • 7GB 19577-2004,冷水机组能效限定值及能源效率等级[S].北京:中国标准出版社,2005.
  • 8ASHRAE.Standard ASHRAE 90.1-1999[EB/OL].http://www.ebookee.net/-share_ebook-ASHRAE-IESNA -Standard-90-1-1999_140478.html.2008-03-05.
  • 9GBT 17981-2007,空气调节系统经济运行[S].北京:中国标准出版社,2008.
  • 10《GB/T蒸气压缩循环冷水(热泵)机组工业或商业用及类似用途的冷水(热泵)机组》(修订)报批稿编制说明.冷冻空调标准与检测,2007,(4):17-21.

引证文献8

二级引证文献17

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部