摘要 常用电磁暂态分析软件,如ATP-EMTP,PSpice等,具有多种电力元件模型,部分还具有传输线的分布参数模型,然而,它们都不能直接研究场-线耦合问题,而场-线耦合传输线模型能完成这项工作,但是无法利用现有电磁暂态软件直接实现它们,Taylor模型是其中常用的一种。为了利用内含分布参数传输线模型的电磁暂态分析软件实现Taylor模型,基于电路理论推导了Taylor模型新型等效电路,使之符合ATP-EMTP等电磁暂态分析软件的分布参数传输线建模特点。分别利用ATP-EMTP软件基于所推导的Taylor模型等效电路,以及Matlab软件基于Fourier变换和逆变换方法,对算例给出的传输线耦合外场的电磁暂态响应进行了计算,结果表明2种方法计算结果较符合,证明所推导的Taylor模型等效电路是正确的,可以利用电磁暂态软件ATP-EMTP对其进行建模。该研究结果的应用可降低场-线耦合研究的复杂度。 The commonly used electromagnetic transient programs(ETP), such as ATP-EMTP, PSpice, etc, can not solve field-to-wire coupling problems, wheras, the field-to-wire coupling models, like the Taylor model, cannot be implemented by the common available ETP softwares. In order to implement the Taylor model in ETP software, we proposed a new equivalent circuit of Taylor model based on electric circuit theory, and calculated the transient response of a transmission line coupling with external field by ATP-EMTP based on the new equivalent circuit of Taylor model and software Matlab based on Fourier and inverse-Fourier transform methods, respectively, and calculation results of the two ways coincide well with each other, showing that the new equivalent circuit of Taylor model is right and is able to be implemented by ATP-EMTP, and can reduce the complexity of field-to-wire coupling research.
出处 《高电压技术》 EI CAS CSCD 北大核心 2012年第9期2360-2365,共6页 High Voltage Engineering
基金 国家自然科学基金(50977091)~~
关键词 电力系统 传输线模型 电磁场 Taylor模型 电磁脉冲效应 电路理论 power system transmission line model electromagnetic field Taylor model electromagnetic pulse effect electric circuit theory
  • 相关文献

参考文献21

  • 1Noda T,Nagaoka N, Ametani A. Phase domain modeling of frequency-dependent transmission lines by means of an ARMA model [J]. IEEE Transactions on Power Delivery, 1996,11(1): 401-411.
  • 2Tuinenga P W. SPICE: a guide to circuit simulation and analysis using PSpice [M]. New Jersey, USA: Prentice-Hall, 1988.
  • 3Agrawal A K,Price H J,Gurbaxani S H. Transient response of multiconductor transmission lines excited by a nonuniform electromagnetic field [J]. IEEE Transactions on Electromagnetic Compatibility, 1980,22(2): 119-129.
  • 4Taylor C D,Satterwhite R S, Harrison C W. The response of a terminated two-wire transmission line excited by a nonuniform electromagnetic field [J]. IEEE Transactions on Antennas and Propagation, 1965,13(6) : 987-989.
  • 5Rachidi F. Formulation of the field-to-transmission line coupling equations in terms of magnetic excitation field[J]. IEEE Transactions on Electromagnetic Compatibility,1993,35(3): 404-407.
  • 6Hoidalen H K. Analytical formulation of lightning-induced volt-ages on multiconductor overhead lines above lossy ground[J]. IEEE Transactions on Electromagnetic Compatibility , 2003, 45 (1): 92-100.
  • 7Hoidalen H K. Calculation of lightning-induced overvoltages u-sing models [C] // International Conference of Power System Transient. Budapest, Hungary: [s. n. ], 1999 : 20-24.
  • 8Hoidalen H K. Calculation of lightning-induced voltages in MODELS including lossy ground effects [ C] // International Conference of Power System Transient. New Orleans, USA: [s. n. ],2003 : 1-6.
  • 9Borghetti A,Gutierrez J A, Nucci C A, et al. Lightning-induced voltages on complex distribution systems: models, advanced software tools and experimental validation[J]. Journal of Electrostatics, 2004,60(2/4) : 163-174.
  • 10Bobrow L S. Elementary linear circuits analysis [M], Oxford, UK: Oxford University Press, 1987.

二级参考文献33

  • 1倪谷炎,罗建书,李传胪.线-面传输线Taylor与Agrawal模型解的比较[J].国防科技大学学报,2007,29(5):111-116. 被引量:11
  • 2谢彦召,王赞基,王群书.地面附近架高线缆HEMP响应计算的Agrawal和Taylor模型比较[J].强激光与粒子束,2005,17(4):575-580. 被引量:39
  • 3徐政.耦合长线电磁暂态分析的扩展Bergeron模型[J].中国电机工程学报,1996,16(5):354-357. 被引量:22
  • 4Ianoz M. Review of new developments in the modeling of lightning electromagnetic effects on overhead lines and buried cables[J]. IEEE Trans. on EMC, 2007, 49(2) : 224 -235.
  • 5Tesche F M, Ianoz M V, Karlsson T. EMC analysis methods and computational models [ M ]. New York: John Wiley&Sons, 1997.
  • 6Bridges G E. Transient plane wave coupling to bare and insulated cables buried in a lossy half-space [ J ]. IEEE Trans. on EMC, 1995, 37 ( 1 ) : 62-70.
  • 7Agrawal A K, Price H J, Gurbaxani S H. Transient response of multiconductor transmission lines excited by a nonuniform elec- tromagnetic field [J]. IEEE Transactions on Electromagnetic Compatibility, 1980, 22(2): 119-129.
  • 8Taylor C D, Satterwhite R S, Harrison C W. The response of a terminated two wire transmission line exeited by a nonuniform e- lectromagnetic field[J]. IEEE Transactions on Antennas Propa- gat, 1965, 13(6): 987-989.
  • 9Rachidi F. Formulation of the field-to-transmission line coupling equations in terms of magnetic excitation field[J]. IEEE Trans actions on Electromagnetic Compatibility, 1993, 35(3): 404- 407.
  • 10Vance E F. Coupling to shielded cables[M]. NewYork, USA: John Wiley and Sons, 1978.

共引文献101

同被引文献34

  • 1邱日强,朱峰,叶家全,杨晓嘉.基于地-线缆耦合的感应电流分析[J].微波学报,2015,31(2):39-44. 被引量:2
  • 2张顺福 邵方殷.500kV输电线路对与之交越的通信线路的静电感应影响及计算.中国电机工程学报,1987,7(3):66-71.
  • 3HJ/T24-1998 500kV超高压送变电工程电磁辐射环境影响评价技术规范[S],1998.
  • 4КАЛАНТАРОВ П Л,ЦЕЙТЛИН Л А.电感计算手册[M].北京:机械工业出版社,1992.
  • 5GB50545-2010110-750kV架空输电线路设计规范[S].2010.
  • 6Tesche F M, Ianoz M V, Karlsson T. EMC analysis methods and com- putational models[M]. New York, USA: John Wiley & Sons, 1999: 109-125.
  • 7郑净明.输电线对通信线电磁感应的计算法[J].电力技术,1981(3):41-44.
  • 8崔鼎新,张顺福.有限长架空电力线路与通信线路之间的互感系数[J].电力技术,1982(1):32-37.
  • 9华京.500kV输电线路对市话线路影响的实例计算分析[c]//全国电磁兼容学术会议论文集.扬州:[出版者不详],2006:6-10.
  • 10Harrington R F. Field computation by moment methods[M]. New York, USA: Macmillan, 1968: 17-43.

引证文献2

二级引证文献5

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部