导出
摘要 目的初步探讨振幅整合脑电图对昏迷患者近期预后的判断价值。方法选择神经重症监护病房(NICU)住院的昏迷患者52例,昏迷程度分为浅昏迷、中昏迷、深昏迷三个水平,发病3d内床旁描记振幅整合脑电图(aEEG),aEEG分为正常aEEG、轻度异常aEEG、重度异常aEEG三类。同时按格拉斯哥-匹兹堡昏迷量表(GPCS)进行评分,分析aEEG分级、GPCS评分在昏迷患者近期预后预测中的价值。结果 aEEG分级的最佳截断点为正常aEEG,GPCS评分的最佳截断点为21~27分;aEEG预测死亡的敏感性、特异性、总正确率分别为79.3%、87.0%、69.2%,GPCS预测死亡的敏感性、特异性、总正确率分别为62.1%、73.9%、69.2%。结论 aEEG可作为客观评估昏迷患者近期预后的指标之一,aEEG预测死亡的准确率高于GPCS评分。
出处 《中国医药指南》 2012年第23期508-509,共2页 Guide of China Medicine
  • 相关文献

参考文献3

  • 1Chen R,Bolton CF,Young B.Prediction of outcome in patiens with anoxic coma:a clinic and eletrophysiologic study[J].Crit Care Med,1996,24(4):672-678.
  • 2Van Rooij LGM,Toet MC,Osredkar D,et al.Recovery of amplitude integrated electroencephalographic background patterns within 24 hours of perinatal asphyxia[J].Arch Dis Child Fetal Neonatal Ed,2005,90(3):245-251.
  • 3Young GB,Doig GS.Continuous EEG monitoring in comatose intensive care patients:epileptiform activity in etiologically distinct groups[J].Neurocrit Care,2005,2(1):5 -10.

同被引文献82

  • 1康涛,刘红磊,刘永红,王金香,王晓丽,邓艳春.眼睑肌阵挛失神癫痫四例临床特征和脑电图特点分析并文献回顾[J].中华临床医师杂志(电子版),2012,6(20):175-177. 被引量:10
  • 2刘旸,王薇薇,吴逊.长程脑电图监测对评估昏迷患者预后的应用价值[J].中华神经科杂志,2007,40(10):667-670. 被引量:17
  • 3Azzopardi D,Robertson NJ,Cowan FM. Pilot study of treatment with whole body hypothermia for neonatal encephalopathy[J].{H}PEDIATRICS,2000,(06):684-694.
  • 4Naqeeb N,Edwards AD,Cowan FM. Assessment of neonatal encephalopathy by amplitude integrated electroencephalography[J].{H}PEDIATRICS,1999,(06):1263-1271.
  • 5Hellstrom-Westas L,de Vries LS,Greisen G. Amplitude-integrated EEG classification and interpretation in preterm and term infants[J].Neoreviews,2006,(01):76-87.
  • 6Lawrence R,Mathur A,Nguyen The Tich S. A pilot study of continuous limited channel aEEG in term infants with encephalopathy[J].{H}Journal of Pediatrics,2009,(11):835-841.
  • 7Spitzmiller RE,Phillips T,Meinzen-DerrJ. Amplitude-integrated EEG is useful in predicting neurodevelopmental outcome in full-term infants with hypoxic-ischemic encephalopathy:a meta-analysis:A Meta-Analysis[J].{H}Journal of Child Neurology,2007,(07):1069-1078.
  • 8Sisman J,Campbell DE,Brion LP. Amplitude-integrated EEG in preterm infants:maturation of background pattern and amplitude voltage with postmenstrual age and gestational age[J].{H}Journal of Perinatology,2005,(06):391-396.
  • 9Mathur AM,Morris LD,Teteh F. Utility of prolonged bedside amplitude-integrated encephalogram in encephalopathic infants[J].Am J Perinatology,2008,(04):611-615.
  • 10ShellhaasRA,Soaita AI,Clancy RR. Sensitivity of amplitude-integrated electroencephalography for neonatal seizure detection[J].{H}PEDIATRICS,2007,(03):770-777.

引证文献7

二级引证文献42

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部